2013
DOI: 10.1007/s00542-013-2025-3
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic chip designs process optimization and dimensional quality control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
23
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 20 publications
(23 citation statements)
references
References 13 publications
0
23
0
Order By: Relevance
“…Nano channels gratings were defined as finger print test structures and molded on Cyclic Olefin Copolymer (COC) Topas 5013 L10. The injection molding process setting levels demonstrated in [10] to improve the replication quality of produced sub-micrometer geometries was used as starting point to define the new optimal process windows used during the molding experiments presented in this work. Replication fidelity between master and polymer geometries produced by conventional IM and ICM was quantified in terms of dimensional deviation from the corresponding nickel nano features.…”
Section: Introductionmentioning
confidence: 99%
“…Nano channels gratings were defined as finger print test structures and molded on Cyclic Olefin Copolymer (COC) Topas 5013 L10. The injection molding process setting levels demonstrated in [10] to improve the replication quality of produced sub-micrometer geometries was used as starting point to define the new optimal process windows used during the molding experiments presented in this work. Replication fidelity between master and polymer geometries produced by conventional IM and ICM was quantified in terms of dimensional deviation from the corresponding nickel nano features.…”
Section: Introductionmentioning
confidence: 99%
“…Micro- and nanocrosses were produced following a procedure reported elsewhere [37]. Each wing of the microfeatures is 5 µm in height and 20 µm in width.…”
Section: Methodsmentioning
confidence: 99%
“…The nano and micro-features produced for this work were created on nickel shim insert; the procedure for fabricating the master geometry is reported elsewhere (Calaon et al, 2013;Menotti et al, 2014). As shown in Figure 1 The mold contained a rectangular cavity with a length of 110 mm, width of 12.7 mm, and thickness of 1.5 mm; the gate had a thickness of 0.5 mm ( Figure 2).…”
Section: Methodsmentioning
confidence: 99%
“…Some methods to reduce the effect due to the interaction between the tip and the sample are reported in the literature (Calaon et al, 2013). In this paper, to reduce the effect due to asymmetry of the tip, two acquisitions were performed for each sample, rotating the sample of 180° after the first acquisition.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
See 1 more Smart Citation