2016
DOI: 10.1080/14756366.2016.1209496
|View full text |Cite
|
Sign up to set email alerts
|

Microextraction by packed sorbent and HPLC–PDA quantification of multiple anti-inflammatory drugs and fluoroquinolones in human plasma and urine

Abstract: We developed and validated an analytical method based on microextraction packed sorbent (MEPS) and high-performance liquid chromatography (HPLC) coupled to photodiode array (PDA) detector to simultaneously quantify multiple nonsteroidal anti-inflammatory drugs (NSAIDs) and fluoroquinolones (FLQs), which may provide as combination several adverse reactions in nephrology and neurology. The linearity range from LOQs (0.1 μg/mL) to 10 μg/mL, and LODs values were 0.03 μg/mL for both NSAIDs and FLQs. The validation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
19
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 46 publications
(19 citation statements)
references
References 23 publications
0
19
0
Order By: Relevance
“…However, the original SPE has undergone numerous modifications to date, mainly related to miniaturization or automatization [20]. Different modalities of miniaturized SPE such as solid-phase microextraction (SPME) [21][22][23][24], stir-bar sorptive extraction (SBSE) [25,26] and microextraction by packed sorbent (MEPS) [27,28] have also been used for the determination of NSAIDs. Magnetic dispersive solid-phase extraction (MDSPE), also called magnetic solid phase extraction (MSPE), uses magnetic or magnetically modified sorbents.…”
Section: Introductionmentioning
confidence: 99%
“…However, the original SPE has undergone numerous modifications to date, mainly related to miniaturization or automatization [20]. Different modalities of miniaturized SPE such as solid-phase microextraction (SPME) [21][22][23][24], stir-bar sorptive extraction (SBSE) [25,26] and microextraction by packed sorbent (MEPS) [27,28] have also been used for the determination of NSAIDs. Magnetic dispersive solid-phase extraction (MDSPE), also called magnetic solid phase extraction (MSPE), uses magnetic or magnetically modified sorbents.…”
Section: Introductionmentioning
confidence: 99%
“…Linear range (μg·mL − 1 ) Detection limit (μg·mL − 1 ) Spectrofluorometric [65] 0.02-2.2 0.006-0.016 HPLC-UV [89] 0.15 to 5 0.04-0.08 HPLC [57] 0.003-1.3 0.001 HPLC-fluorescence [90] 0.005-0.1 0.0005-0.005 Capillary electrophoresis [83] 5-20 1.1 and 2.4 Chemiluminescence [77] 1.98 × 10 − 9 0.003-7 HPLC-PDA [91] 0.1-10 0.03 Spectrophotometric [72] 0.5-25 0.084 HPLC [92] 0.0005-1 0.00007 is method 0.25-20 0.035-0.093 International Journal of Analytical Chemistry substances on the proposed method for the determination of ciprofloxacin.…”
Section: Methodsmentioning
confidence: 99%
“…6 FQs contaminations create a serious threat to human health due to their harmful effects, such as drug resistant pathogens and causing allergic reactions. [7][8][9][10][11][12] Numerous methods have been developed for the determination of FQs in environmental water, bio-uids, and foodstuffs etc., including electrochemical methods, 13 liquid chromatography tandem mass spectrometry (LC-MS/MS), 14,15 high performance liquid chromatography with ultraviolet detection (HPLC-UV), 16,17 high-performance liquid chromatography coupled to photodiode array (HPLC-PDA), 18 and enzyme immunoassays. 19,20 However, laborious sample pretreatments (e.g., centrifugation and chemical pre-extraction, etc.)…”
Section: Introductionmentioning
confidence: 99%