2008
DOI: 10.1016/j.chroma.2008.07.023
|View full text |Cite
|
Sign up to set email alerts
|

Microcalorimetric study of adsorption of human monoclonal antibodies on cation exchange chromatographic materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 30 publications
(32 citation statements)
references
References 31 publications
1
31
0
Order By: Relevance
“…The microcalorimetric measurements were carried out with an ITC4200 microcalorimeter (Calorimetry Science Corp., Lindon, NY, USA) as previously described in [9]. The 1 ml sample ampoule was filled with the desired amount of adsorbent (20-80 L) using a MediaScout ResiQuot device (Atoll GmbH, Weingarten, Germany).…”
Section: Isothermal Titration Calorimetrymentioning
confidence: 99%
See 2 more Smart Citations
“…The microcalorimetric measurements were carried out with an ITC4200 microcalorimeter (Calorimetry Science Corp., Lindon, NY, USA) as previously described in [9]. The 1 ml sample ampoule was filled with the desired amount of adsorbent (20-80 L) using a MediaScout ResiQuot device (Atoll GmbH, Weingarten, Germany).…”
Section: Isothermal Titration Calorimetrymentioning
confidence: 99%
“…The evaluation of the ITC data and the calculation of the specific enthalpy of adsorption were carried out as previously described in [9] and are not discussed here in detail. Preliminary experiments showed that the contribution of the adsorption of buffer ions and the heat of dilution of buffer ions to the measured signal can be neglected here.…”
Section: Evaluation Of Itc Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Combining this with the Langmuir isotherm, the equilibrium constant can be calculated as q approaches zero, 15,32…”
Section: Calorimetric Measurements Of Lysozyme Adsorption On Ha-smentioning
confidence: 99%
“…ITC has been successfully used to acquire thermodynamic data in protein adsorption on various ion exchange and hydrophobic interaction adsorbents. [13][14][15] For this purpose, we synthesized a histamine-Sepharose (HA-S) gel with higher ligand density than the histamine-ligand chromatography media reported previously. [16][17][18] Lysozyme was chosen for adsorption onto HA-S because it has been used extensively as a model protein for fundamental researches on chromatographic techniques.…”
Section: Introductionmentioning
confidence: 99%