2009
DOI: 10.1016/j.jcis.2008.09.066
|View full text |Cite
|
Sign up to set email alerts
|

Microbubble size isolation by differential centrifugation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

10
381
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 390 publications
(398 citation statements)
references
References 37 publications
10
381
0
Order By: Relevance
“…Once the animal, the targeting coordinates, and the FUS system were set, negative control sonications were performed in the absence of microbubbles (see Figure 2 and below for details). After IV injection of monodispersed 4-5-mm microbubbles that were manufactured inhouse and size-isolated using differential centrifugation [18], the animals were sonicated for a total duration of 2 minutes with an estimated focal maximum pressures ranging between 0.20 and 0.30 MPa. Those microbubbles are generally used as ultrasonic contrast agent and they are evacuated very rapidly from the system through the lungs and kidneys (half-life time in humans: 5-10 minutes typically).…”
Section: Ethics Statementmentioning
confidence: 99%
“…Once the animal, the targeting coordinates, and the FUS system were set, negative control sonications were performed in the absence of microbubbles (see Figure 2 and below for details). After IV injection of monodispersed 4-5-mm microbubbles that were manufactured inhouse and size-isolated using differential centrifugation [18], the animals were sonicated for a total duration of 2 minutes with an estimated focal maximum pressures ranging between 0.20 and 0.30 MPa. Those microbubbles are generally used as ultrasonic contrast agent and they are evacuated very rapidly from the system through the lungs and kidneys (half-life time in humans: 5-10 minutes typically).…”
Section: Ethics Statementmentioning
confidence: 99%
“…A polyacrylamide phantom with a channel of 4 mm in diameter was made to contain the in-house manufactured lipid-shelled monodisperse MB with a gas core of perfluorobutane (median diameter: 4-5 ÎŒm, concentration: 1×10 9 bubbles/mL) 13 , and the 4-mm channel was chose to include the -6 dB focus of the transducer. A single-element FUS transducer was applied (center frequency or fc: 500 kHz, focal length: 62.6 mm, focal width and depth in -6 dB: 5.85 mm and 34 mm) with a flat-band hydrophone (sensitivity: 0.01-15 MHz) at the center (Sonic Concepts Inc., WA, USA) served as PCD.…”
Section: Phantom Experiments and Proceduresmentioning
confidence: 99%
“…b) Bubbles can be sorted using the difference in gravitational force acting on bubbles of different size. Centrifugation of the bubble suspension can be applied to increase the efficiency of this sorting technique 83 . c) The buoyancy force can also be used through decantation 82,87 , the larger bubbles rise faster in a fluid than the smaller bubbles.…”
Section: Discussionmentioning
confidence: 99%
“…by filtering 79 or by decantation 82 . A selection of bubbles can also be extracted by means of centrifugation 83 or by using a microfluidic sorting strategy, e.g. using pinched flow fractionation 84 .…”
Section: Sorting Techniquesmentioning
confidence: 99%
See 1 more Smart Citation