2017
DOI: 10.1109/tuffc.2017.2741067
|View full text |Cite
|
Sign up to set email alerts
|

Microbubble Axial Localization Errors in Ultrasound Super-Resolution Imaging

Abstract: Abstract-Acoustic super-resolution imaging has allowed visualization of microvascular structure and flow beyond the diffraction limit using standard clinical ultrasound systems through the localization of many spatially isolated microbubble signals. The determination of each microbubble position is typically performed by calculating the centroid, finding a local maximum, or finding the peak of a 2-D Gaussian function fit to the signal. However, the backscattered signal from a microbubble depends not only on di… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
55
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
4
2

Relationship

4
6

Authors

Journals

citations
Cited by 77 publications
(59 citation statements)
references
References 41 publications
0
55
1
Order By: Relevance
“…The step after the SVD filtering consists of localizing the MB positions. Several methods have been used for this purpose, such as onset detection, centroid fitting, Gaussian fitting, and others which have been previously compared (Christensen-Jeffries et al 2017). In this study, the centroid method was used due to its adequate computational performance and its ease of implementation.…”
Section: Microbubble Localizationmentioning
confidence: 99%
“…The step after the SVD filtering consists of localizing the MB positions. Several methods have been used for this purpose, such as onset detection, centroid fitting, Gaussian fitting, and others which have been previously compared (Christensen-Jeffries et al 2017). In this study, the centroid method was used due to its adequate computational performance and its ease of implementation.…”
Section: Microbubble Localizationmentioning
confidence: 99%
“…SVD was used to separate the microbubble signals from the echoes originating from the tube and the assembly holding the tube. Localization of isolated microbubbles was performed on every acquired volume to generate the 3-D super-resolved volumes [33].…”
Section: B Experimental Setupmentioning
confidence: 99%
“…Motion estimation was performed on the 3-D B-mode data and microbubble locations were corrected accordingly. Localization of isolated microbubbles was performed using the onset method on every acquired volume to generate the 3-D SR-US images [27].…”
Section: -D Microvascular Flow Simulationmentioning
confidence: 99%