2007
DOI: 10.2485/jhtb.16.91
|View full text |Cite
|
Sign up to set email alerts
|

Micro-CT Analysis of Rabbit Cancellous Bone Around Implants

Abstract: OriginalAbstract:The aim of this study is to observe the three-dimensional structure of cancellous bone formed around dental implants using micro-CT.Methods: Ti implants (Ti-15%Zr-

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 11 publications
(12 reference statements)
0
4
0
Order By: Relevance
“…Therefore, in this study we chose to perform a computed tomographic evaluation before the samples were cut and ground in order to obtain a detailed view of the interface. Micro-CT is a reliable non-invasive analytical instrument to quantify the amount of mineralized bone around artificial implants and characterize the bone structures [ 45 , 46 ]. Together with the histological sections, a comprehensive image of the bone can be surveyed and provide a representative description of the healing event.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, in this study we chose to perform a computed tomographic evaluation before the samples were cut and ground in order to obtain a detailed view of the interface. Micro-CT is a reliable non-invasive analytical instrument to quantify the amount of mineralized bone around artificial implants and characterize the bone structures [ 45 , 46 ]. Together with the histological sections, a comprehensive image of the bone can be surveyed and provide a representative description of the healing event.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, micro CT is frequently used for the study of trabecular structure and hard tissue ultrastructure, and has been applied to studies in various medical fields 35,36) . In animal experiments involving implants, observation by micro CT may not be reliable because measurement of areas close to the implant is difficult due to the artifacts 37,38) . Therefore, in this experiment, rabbit femurs were used after the implants had been removed.…”
Section: Discussionmentioning
confidence: 99%
“…Micro-CT can well distinguish the fine structure inside the bone tissue of beagle dogs and can quantitatively analyze the bone reconstruction around the implant (Numata et al, 2007). To quantitatively analyze the osteogenesis difference between different implants, the three-dimensional bone reconstruction of bone growth Figure 14 is a three-dimensional reconstruction model of the control group and Figure 15 is a three-dimensional reconstruction model of the experimental group.…”
Section: Surface Coating Treatmentmentioning
confidence: 99%