2013
DOI: 10.1007/s00784-013-0982-7
|View full text |Cite
|
Sign up to set email alerts
|

Micro-computerized tomographic analysis of premolars restored with oval and circular posts

Abstract: The microCT analysis provided interesting information on voids distribution and on the ratio between post shape and cement thickness. These results might address the clinician in the reconstruction of teeth with fiber posts.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
41
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(46 citation statements)
references
References 32 publications
4
41
0
1
Order By: Relevance
“…This then increases the shrinkage stress induced by polymerization of the resin cement [15,16]. Although many in-vitro studies have investigated the influence of cement thickness [16][17][18][19][20][21][22] and voids [16,[23][24][25] on the bond strength of fiber posts, there is no consensus in the literature.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…This then increases the shrinkage stress induced by polymerization of the resin cement [15,16]. Although many in-vitro studies have investigated the influence of cement thickness [16][17][18][19][20][21][22] and voids [16,[23][24][25] on the bond strength of fiber posts, there is no consensus in the literature.…”
Section: Introductionmentioning
confidence: 99%
“…Another disadvantage of sectioning is that only a limited number of sections per specimen can be evaluated, and only the area of cement and voids can be analyzed [18,19]. Micro-CTs have recently been used to differentiate between canal walls, cement, and fiber post, and show that 3D quantitative assessment of post space volume is possible [17]. Moreover, through this technique any potential operator bias during interpretation of the results could be avoided [28].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…No que diz respeito à influência da espessura da linha de cimento resinoso sobre a resistência de união de pinos de fibra, não há consenso na literatura sobre a espessura ideal da interface de cimento resinoso para otimizar a retenção de um pino (95). Alguns estudos de resistência de união sugerem que a espessura de cimento não afeta significativamente a resistência de união dos pinos de fibra à dentina radicular (101,102).…”
Section: Experimento 2 -Resistência De Uniãounclassified