1998
DOI: 10.1016/s1011-1344(98)00122-5
|View full text |Cite
|
Sign up to set email alerts
|

Mexoryl® SX: a broad absorption UVA filter protects human skin from the effects of repeated suberythemal doses of UVA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
60
0
3

Year Published

2005
2005
2024
2024

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 103 publications
(65 citation statements)
references
References 16 publications
2
60
0
3
Order By: Relevance
“…ROS production in fibroblasts was initially established using moderate UVA doses of up to 18 J/cm 2 by measuring the fluorescence emitted from the oxidized carboxy-H 2 DCFDA ROSindex probe. This is a biologically relevant dose equivalent to that received by human skin exposed to clear midday, midsummer sun, for a short period of time [28,29]. The results reported in Fig.…”
Section: Resultsmentioning
confidence: 97%
“…ROS production in fibroblasts was initially established using moderate UVA doses of up to 18 J/cm 2 by measuring the fluorescence emitted from the oxidized carboxy-H 2 DCFDA ROSindex probe. This is a biologically relevant dose equivalent to that received by human skin exposed to clear midday, midsummer sun, for a short period of time [28,29]. The results reported in Fig.…”
Section: Resultsmentioning
confidence: 97%
“…Data obtained in reconstructed skin in vitro were, thus, in agreement with studies performed in vivo with the same sunscreen formulations. 17,22,23 …”
Section: Evaluation Of the Efficiency Of Sunscreens Using An Organotymentioning
confidence: 99%
“…The cream 50B-10A containing or not pre-tocopheryl was applied to the epidermis. Then UV radiation was performed as previously described [10] in order to rapidly induce damages to the fi brous components of the dermis as those observed in vivo [11,12] . The source of UV radiation was a Vilbert Lourmat stimulator (France) fi tted out with a UVB irradiation source composed of Vilbert Lourmat tubes T-15.M-312 (no UVA, no UVC emission), a UVA irradiation source composed of Vilbert Lourmat tubes T-15.L-365 (no UVB, no UVC emission), mercury vapour tubes, low pressure, and hot cathodes with a Vilbert Lourmat RMX-365/312 radiometer with a programmable microprocessor (measuring energy, in mJ/cm 2 ) and a time basis enabling 6 irradiation measurements per second for the control of energy received by the skin fragment.…”
Section: Uv Radiation Of Normal Human Skin Specimens Maintainedmentioning
confidence: 99%