2021
DOI: 10.1016/j.asr.2020.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Metrology on-board PROBA-3: The shadow position sensors subsystem

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(6 citation statements)
references
References 20 publications
(24 reference statements)
0
6
0
Order By: Relevance
“…At the nominal alignment conditions, at ISD=144m, we expect to have an SPS readout around 1037 DN so the error expected is about 1.0-1.5DN (1σ). From the qualification of the electronic chain [9], we know that the relation between DN and corresponding lateral shift is 10μm/DN so the contribution of the temporal stability of the SPS readout, within the requirement box (sec.2), remains of the order of 15μm. This contribution is in good agreement with the results obtained by performance analysis and it will be included in the overall error budget to confirm the final error, with the contribution of the electronics and of the numerical calculation (algorithm).…”
Section: Time Stability Test Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…At the nominal alignment conditions, at ISD=144m, we expect to have an SPS readout around 1037 DN so the error expected is about 1.0-1.5DN (1σ). From the qualification of the electronic chain [9], we know that the relation between DN and corresponding lateral shift is 10μm/DN so the contribution of the temporal stability of the SPS readout, within the requirement box (sec.2), remains of the order of 15μm. This contribution is in good agreement with the results obtained by performance analysis and it will be included in the overall error budget to confirm the final error, with the contribution of the electronics and of the numerical calculation (algorithm).…”
Section: Time Stability Test Resultsmentioning
confidence: 99%
“…In order to achieve the formation-flying objectives, a suite of metrology systems will provide continuous measurements of the satellites relative and absolute position down to sub-millimetre precision [6]. Among these, the Shadows Position Sensors (SPS) is expected to return the position measurement with the highest accuracy [7]. The SPS unit consists of a mechanical flange mounted in front of the ASPIICS telescope boom, hosting an electronic board where a set of eight silicon photo-multipliers (SiPMs), positioned along a circumference concentric with the telescope entrance pupil, will measure the solar penumbra irradiance as projected by the external occulter.…”
Section: Proba3 Mission and The Shadow Position Sensors (Sps)mentioning
confidence: 99%
See 3 more Smart Citations