2013
DOI: 10.1111/jphp.12109
|View full text |Cite
|
Sign up to set email alerts
|

Metoprolol oxidation polymorphism in Brazilian elderly cardiac patients

Abstract: Most of the studied individuals were women, and the proportion of elderly with heart disease classified as PM was smaller than what is usually found among Caucasian populations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 36 publications
0
9
0
Order By: Relevance
“…Aliquots of 100 μL of plasma supplemented with tramadol as an internal standard (50 μg/ml), 25 μL of 1 M sodium hydroxide aqueous solution, 10 mg of sodium chloride and 2 mL of dichloromethane-diisopropyl ether (1:1, v/v). The compounds were separated on an RP Select B column (LiChrospher®60 Merck, Darmstadt, Germany) using buffer phosphate (0.05 M and pH 3.5) and acetonitrile (90:10, v/v) as the mobile phase and analyzed using a fluorescence detector (229 and 298 nm) [23, 24]. Calibration curves were constructed from 20 to 1000 ng metoprolol/mL and from 10 to 500 ng α-hydroxymetoprolol/mL.…”
Section: Methodsmentioning
confidence: 99%
“…Aliquots of 100 μL of plasma supplemented with tramadol as an internal standard (50 μg/ml), 25 μL of 1 M sodium hydroxide aqueous solution, 10 mg of sodium chloride and 2 mL of dichloromethane-diisopropyl ether (1:1, v/v). The compounds were separated on an RP Select B column (LiChrospher®60 Merck, Darmstadt, Germany) using buffer phosphate (0.05 M and pH 3.5) and acetonitrile (90:10, v/v) as the mobile phase and analyzed using a fluorescence detector (229 and 298 nm) [23, 24]. Calibration curves were constructed from 20 to 1000 ng metoprolol/mL and from 10 to 500 ng α-hydroxymetoprolol/mL.…”
Section: Methodsmentioning
confidence: 99%
“…The intra-and interday accuracy (relative standard error) and precision (coefficient of variation) ranged from −4.0% to 12.0% and 1.9% to 10.4%, respectively. 22 Pharmacokinetic and Statistical Analysis Noncompartmental analysis was performed using Phoenix 64 WinNonlin software version 8.3.4.295 (Certara, Princeton, NJ, USA). The elimination half-life was derived from the terminal slope of the plasma concentration-time profile.…”
Section: Drug Analysismentioning
confidence: 99%
“…Subjects were stratified as PMs when MR was >12.6. 22,23 Statistical analyses were performed using RStudio Team version 2022.07.1 (R Stats and ggplot2 packages; RStudio, PBC, Boston, MA, USA). The distribution of PK parameters was evaluated by visual inspection of histograms of probability density and quantilequantile graphs, and by the Shapiro-Wilk test.…”
Section: Drug Analysismentioning
confidence: 99%
“…Samples. The analytical method of analysis of metoprolol and α-hydroxymetoprolol in plasma samples was developed by high-performance liquid chromatography and fluorescence detector operating at 229 and 298 nm, according to the method previously validated by our research group, 33,34 Analysis of Omeprazole, Hydroxyomeprazole, and Omeprazole Sulfone in Plasma Samples. The analytical method of analysis of omeprazole, hydroxyomeprazole, and omeprazole sulfone in plasma samples was conducted by high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS), as previously described by our research group.…”
Section: Analysis Of Metoprolol and α-Hydroxymetoprolol In Plasmamentioning
confidence: 99%
“…Samples. The analytical method of analysis of metoprolol and α-hydroxymetoprolol in plasma samples was developed by high-performance liquid chromatography and fluorescence detector operating at 229 and 298 nm, according to the method previously validated by our research group, 33,34 with modifications. Briefly, aliquots of μL of plasma spiked with 25 μL of internal standard solution (tramadol 50 μg/mL) were alkalinized with 250 μL of 1 M sodium hydroxide and extracted with 4 mL of dichloromethane:diisopropyl ether (1:1, v/v) for 30 minutes on a horizontal shaker.…”
Section: Analysis Of Metoprolol and α-Hydroxymetoprolol In Plasmamentioning
confidence: 99%