2021
DOI: 10.1007/s10570-021-04301-y
|View full text |Cite
|
Sign up to set email alerts
|

Methylene blue adsorption onto hydrogels made from different Eucalyptus dissolving pulps

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 100 publications
0
4
0
Order By: Relevance
“…CCE17.5 and CCE35 presented a carboxyl content of 0.038 and 0.047 mmol/g, respectively ( Figure 7 ). On the other hand, the shorter cellulose chains of CCE17.5 and CCE35 samples also contributed to increase the access to the internal structure of fibers allowing the diffusion of ions involved in the conductimetric titration [ 38 ]. The amount of carboxyl groups in pine (from 0.032 to 0.021 mmol/g) was significantly lower than eucalyptus.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…CCE17.5 and CCE35 presented a carboxyl content of 0.038 and 0.047 mmol/g, respectively ( Figure 7 ). On the other hand, the shorter cellulose chains of CCE17.5 and CCE35 samples also contributed to increase the access to the internal structure of fibers allowing the diffusion of ions involved in the conductimetric titration [ 38 ]. The amount of carboxyl groups in pine (from 0.032 to 0.021 mmol/g) was significantly lower than eucalyptus.…”
Section: Resultsmentioning
confidence: 99%
“…Curve fitting was performed using PeakFit software (Systat, Software Inc., San Jose, CA, USA) to identify individual peaks. The detailed deconvolution procedure can be found in Carrillo-Varela et al [ 38 ]. In all cases, the F number was >45,000 (R 2 < 0.997).…”
Section: Methodsmentioning
confidence: 99%
“…Fourier transform infrared (FT-IR) spectra of the KL, SMPs, and KL–SMPs fabricated at −20 °C were recorded in the range of 4000–400 cm –1 on a PerkinElmer spectrophotometer with a KBr standard. The crystal phase of the KL, SMPs, and KL–SMPs was analyzed using X-ray diffraction (XRD; D8 Advance X-ray diffractometer, Bruker, Germany) from 3 to 60° (2θ) using Cu Kα radiation (1.54 Å); the percentage of crystallinity of KL–SMPs was estimated from the resulting spectra by calculating the ratio between the area of the peaks and the total area . All samples were dried in a vacuum dryer overnight before the measurement.…”
Section: Methodsmentioning
confidence: 99%
“…The crystal phase of the KL, SMPs, and KL−SMPs was analyzed using X-ray diffraction (XRD; D8 Advance X-ray diffractometer, Bruker, Germany) from 3 to 60°(2θ) using Cu Kα radiation (1.54 Å); the percentage of crystallinity of KL−SMPs was estimated from the resulting spectra by calculating the ratio between the area of the peaks and the total area. 25 All samples were dried in a vacuum dryer overnight before the measurement. The ultraviolet− visible (UV−vis) optical absorption spectra and diffuse reflectance spectra of the SMPs and KL−SMPs were analyzed in the 200−800 nm range using an Agilent Cary 7000 UV−vis spectrophotometer.…”
Section: Fabrication Of Kl-embedded Starch Microparticles (Kl− Smps)mentioning
confidence: 99%