1969
DOI: 10.1364/josa.59.0223_1
|View full text |Cite
|
Sign up to set email alerts
|

Methods of Representing Emission, Excitation, and Photoconductivity Spectra

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
32
0

Year Published

1972
1972
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(32 citation statements)
references
References 5 publications
0
32
0
Order By: Relevance
“…The luminous efficacy and the average photon energy can then be determined using Equations (2) and (3), in combination with the known eye sensitivity curve V(λ) [23]: η=ϕe(λ)V(λ)normaldλϕe(λ)normaldλ Efalse¯γ=ϕγ(E)EnormaldEϕγ(E)normaldE where ϕe(λ) is the spectral radiant flux, which is related to the photon flux by ϕe(λ)dλ=ϕγ(λ)hcλdλ. Care should be taken when converting a flux per wavelength interval into a flux per energy interval, as the relation in Equation (4) holds [44]: normaldϕ(E)normaldEλ2normaldϕ(λ)normaldλ…”
Section: Resultsmentioning
confidence: 99%
“…The luminous efficacy and the average photon energy can then be determined using Equations (2) and (3), in combination with the known eye sensitivity curve V(λ) [23]: η=ϕe(λ)V(λ)normaldλϕe(λ)normaldλ Efalse¯γ=ϕγ(E)EnormaldEϕγ(E)normaldE where ϕe(λ) is the spectral radiant flux, which is related to the photon flux by ϕe(λ)dλ=ϕγ(λ)hcλdλ. Care should be taken when converting a flux per wavelength interval into a flux per energy interval, as the relation in Equation (4) holds [44]: normaldϕ(E)normaldEλ2normaldϕ(λ)normaldλ…”
Section: Resultsmentioning
confidence: 99%
“…and Eq(ii) for quinine in 1 N H2 S04 are plotted on the same graph. The relation between the various units for emission spectra can be shown from the work of Ejder [9] to be:…”
Section: B Presentation Of Emission Spectramentioning
confidence: 99%
“…All spectra were measured at room temperature and corrected for the spectral response of the detection system by calibration with a tungsten lamp. 50 Transmission electron microscopy (TEM) analyses were accomplished on a G2 Spirit BioTWIN TEM (Tecnai) using a LaB 6 120 kV electron beam. Images were recorded by an SIS Veleta side-mounted CCD camera (Olympus) with 4 megapixels at 30 000-fold magnication (pictures with 500 nm scale), 100 000-fold magnication (picture with 200 nm scale), and 300 000-fold magnication (pictures with 50 nm scale).…”
Section: Experimental Methodsmentioning
confidence: 99%