1992
DOI: 10.1039/ft9928803553
|View full text |Cite
|
Sign up to set email alerts
|

Methods for the determination of transport parameters of gases in membranes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

1994
1994
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…The density was calculated using the following equation (Equation (A7)):ρitalicmembrane=wairwairwliq×ρliqWith ρ membrane being the membrane density (g/cm 3 ), w air and w liq being the weight of the membrane in air and FC-77 (g), respectively, and ρ liq being the density of FC-77 (g/cm 3 ). Gas permeability was measured by a “time-lag” experimental facility developed in-house using constant volume variable pressure approach for permeability and diffusion coefficients determination [51]. The facility has already been discussed elsewhere [4,52].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The density was calculated using the following equation (Equation (A7)):ρitalicmembrane=wairwairwliq×ρliqWith ρ membrane being the membrane density (g/cm 3 ), w air and w liq being the weight of the membrane in air and FC-77 (g), respectively, and ρ liq being the density of FC-77 (g/cm 3 ). Gas permeability was measured by a “time-lag” experimental facility developed in-house using constant volume variable pressure approach for permeability and diffusion coefficients determination [51]. The facility has already been discussed elsewhere [4,52].…”
Section: Methodsmentioning
confidence: 99%
“…Gas permeability was measured by a “time-lag” experimental facility developed in-house using constant volume variable pressure approach for permeability and diffusion coefficients determination [51]. The facility has already been discussed elsewhere [4,52].…”
Section: Methodsmentioning
confidence: 99%
“…Gas permeability characterization has been carried out by a "time-lag" experiment facility developed in-house utilizing constant volume variable pressure approach for permeability and diffusion coefficients determination [31]. The facility was already discussed elsewhere [32] and the method was just slightly adapted to the measurements of liquids as proposed by Ferguson et al.…”
Section: "Time-lag" Experimentsmentioning
confidence: 99%
“…In case in which the downstream chamber the pressure has a time dependent concentration the expression of eq. (2) should be corrected as Cruden and Meyyappan [16], and they show that the first correction of the time lag expression is twice in the Nguyen´s work [17], and in the linear approximation the right diffusion uncertainty that it is by a factor of 3 [18].…”
Section: Introductionmentioning
confidence: 99%