Methods for sampling and analysis of the aqueous phase of human dental plaque

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
12
0

Year Published

1976
1976
2010
2010

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(13 citation statements)
references
References 15 publications
1
12
0
Order By: Relevance
“…21 One hour after sucrose rinses the plaque fluid in the caries-positive individuals fell to 5.88 AE 0.37. 21 Other authors have studied plaque fluid pH and obtained values of 5.73 AE 0.22, 22 6.54 AE 0.30, 23 5.73 AE 0.79 24 and 6.76 AE 0.04. 25 The surface pH of sound enamel and WSEL reported in this study are similar to the plaque fluid measurements reported by Margolis and Moreno 21 and within the range reported by the other authors.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…21 One hour after sucrose rinses the plaque fluid in the caries-positive individuals fell to 5.88 AE 0.37. 21 Other authors have studied plaque fluid pH and obtained values of 5.73 AE 0.22, 22 6.54 AE 0.30, 23 5.73 AE 0.79 24 and 6.76 AE 0.04. 25 The surface pH of sound enamel and WSEL reported in this study are similar to the plaque fluid measurements reported by Margolis and Moreno 21 and within the range reported by the other authors.…”
Section: Discussionmentioning
confidence: 97%
“…25 The surface pH of sound enamel and WSEL reported in this study are similar to the plaque fluid measurements reported by Margolis and Moreno 21 and within the range reported by the other authors. [22][23][24][25] Therefore, the surface pH measurements may reflect the pH of that environment prior to plaque removal and may relate to the pH of the enamel fluid.…”
Section: Discussionmentioning
confidence: 99%
“…Assuming a calcium ion activity product in plaque fluid of 1-2 mM [Tatevossian and Gould, 1976;Vogel et al, 2000], it can easily be calculated that a fluoride concentration of only a few ppm is required to fulfill the solubility product of calcium fluoride [Øgaard, 1985]. Surface adsorption of fluoride to crystal surfaces may cause local higher concentrations of fluoride than in plaque fluid.…”
Section: Calcium Fluoride Formationmentioning
confidence: 99%
“…To illustrate this point, devices were removed from the volunteers and immediately transported to the laboratory in a hu midified collecting vessel (time § 5 min). The device, with the plaque undisturbed within, was then exposed to solutions, approximating to the inorganic composition of saliva [Tatevossian and Gould, 1976], containing either 5 pCi/ml l4C-sucrose or 5 pCi/ntl ,2P-phosphate in 60 mM Tris, 130 mM KCI, 1.5 mM Ca(NO,):4 H :0. 3m M KH: P 0 4, pH 71 for 30 s. The device was then briefly dipped into a wash solution containing the buffer only, carefully blotted with paper tissue and snap frozen as described above.…”
Section: Determination O F Penetration O F 14 C-sucrose and 32 P-phosmentioning
confidence: 99%