2016
DOI: 10.1049/hve.2016.0007
|View full text |Cite
|
Sign up to set email alerts
|

Methods for recording the time profile of single ultrashort pulses of electron beams and discharge currents in real‐time mode

Abstract: The collectors for measuring the time profile of a current pulse of the runaway electron beam that are generated under atmospheric pressure are described. An analysis of changes in pulse shape depending on the bandwidth of the registration path with a temporal resolution of up to 20 ps was performed. It is shown that the electron beam detected behind small-diameter diaphragms has a complex structure, which depends on the parameters of the gas diode. There is a design of the current shunts with a temporal resol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 27 publications
0
11
0
Order By: Relevance
“…The effect of gas pressure on the amplitude and duration of the SAEB is shown. Synchronisation method of SAEB current pulses with voltage and discharge current pulses is described in [55]. Fig.…”
Section: Spatial Forms Of Rep Dd In Different Gasesmentioning
confidence: 99%
“…The effect of gas pressure on the amplitude and duration of the SAEB is shown. Synchronisation method of SAEB current pulses with voltage and discharge current pulses is described in [55]. Fig.…”
Section: Spatial Forms Of Rep Dd In Different Gasesmentioning
confidence: 99%
“…This was combined with a transmission line (wave impedance Z is 75 Ω) equipped with a capacitive voltage divider (CVD). A detailed description and study of the capabilities of the measuring sensors (CVDs, current shunts, collectors) used in the setup are described in [19,20].…”
Section: Experimental Setup and Methodsmentioning
confidence: 99%
“…1 and 3, the diameters of the collector's receiving parts were 20 and 13 mm, respectively. Temporal resolutions of ones were 80 and 50 ps, respectively, [38]. The signals from these sensors were transmitted to a DSO‐X6004A digital real‐time oscilloscope (6 GHz, 20 GS/s) (Keysight Technologies, USA) via RG58‐A/U high‐frequency cables (Antenna Network Lab Inc., USA) having a length of 1.5 m with N‐type connectors Suhner 11 N‐50‐3‐28/133 NE (HUBER + SUHNER, Switzerland) and SMA connectors Radiall R125.075.000 (Radiall, France).…”
Section: Methodsmentioning
confidence: 99%
“…2, the collector's receiving part was 30 mm in diameter. Its temporal resolution was 150 ps [38]. The signals from the detectors were transmitted via RF cables with length of 4 m to a LeCroy WaveMaster 808Zi‐A digital real‐time oscilloscope (8 GHz, 40 GS/s), having a temporal resolution better than 80 ps.…”
Section: Methodsmentioning
confidence: 99%