2019
DOI: 10.1103/physrevd.100.023538
|View full text |Cite
|
Sign up to set email alerts
|

Methods for pixel domain correction of EB leakage

Abstract: In observation of the cosmic microwave background (CMB) polarization, "EB leakage" refers to the artificial B-mode signal coming from the leakage of E-mode signal when part of the sky is unavailable or excluded. Correction of such leakage is one of the preconditions for detecting primordial gravitational waves via the CMB B-mode signal. In this work, we design two independent methods for correcting the EB leakage directly in the pixel domain using standard definitions of the Eand B-modes. The two methods give … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
33
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 24 publications
(33 citation statements)
references
References 56 publications
(67 reference statements)
0
33
0
Order By: Relevance
“…Interestingly, as shown by Fig. 1, for pure CMB signal, the error bars of the recycling method [3] are roughly only 30% bigger than the ideal error bars, thus the result of the recycling method is an excellent approximation of the BUE, especially when computed at a higher resolution. However, as mentioned above, this must to be further tested if non-Gaussian and non-analytic prior information is taken into account.…”
Section: Summary and Discussionmentioning
confidence: 85%
See 3 more Smart Citations
“…Interestingly, as shown by Fig. 1, for pure CMB signal, the error bars of the recycling method [3] are roughly only 30% bigger than the ideal error bars, thus the result of the recycling method is an excellent approximation of the BUE, especially when computed at a higher resolution. However, as mentioned above, this must to be further tested if non-Gaussian and non-analytic prior information is taken into account.…”
Section: Summary and Discussionmentioning
confidence: 85%
“…We know from Figure 1 that the BUE only gives 20-30% improvement compared to the recycling method used in [3,4], which is sufficiently fast. Meanwhile, it was shown by Figure 6 of [9] that for ≈ 100, the error of the fisher estimator is no less than 50% of the pseudo-C method.…”
Section: Estimation Of the Maximal Abilitymentioning
confidence: 91%
See 2 more Smart Citations
“…However, it is important to stress, that component separation and extraction of the primordial CMB polarised signal usually takes place in Q, U domain and only then is converted into E/B components. This conversion is not local and for different masks is accompanied by the presence of different E-to-B leakage terms [5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%