2022
DOI: 10.1016/j.ijms.2022.116848
|View full text |Cite
|
Sign up to set email alerts
|

Methods and limitations of stable isotope measurements via direct elution of chromatographic peaks using gas chromotography-Orbitrap mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 38 publications
0
8
0
Order By: Relevance
“…This platform employed a Thermo Scientific TRACE™ 1310 GC equipped with split/splitless injector. Peaks eluting directly off the GC column have been explored for isotope analysis, illustrating that the achievable precision is limited by the number of ions (10 4 –10 5 ) observed per scan in the Orbitrap and the width of the chromatographic peak (in time) 43 . Our application therefore required a distinct instrumental setup to achieve the desired precision (i.e.…”
Section: Methodsmentioning
confidence: 99%
“…This platform employed a Thermo Scientific TRACE™ 1310 GC equipped with split/splitless injector. Peaks eluting directly off the GC column have been explored for isotope analysis, illustrating that the achievable precision is limited by the number of ions (10 4 –10 5 ) observed per scan in the Orbitrap and the width of the chromatographic peak (in time) 43 . Our application therefore required a distinct instrumental setup to achieve the desired precision (i.e.…”
Section: Methodsmentioning
confidence: 99%
“…We measured the d 13 C VPDB values of the five PAHs previously identified in Hayabusa2 sample A0106 and the d 13 C VPDB , dD VSMOW and D2× 13 C values of the same five PAHs from C0107 (21). We compared these measurements with those of fluoranthene and pyrene extracted from the CC meteorite Murchison (21,31). We also measured d 13 C VPDB and D2× 13 C values of combusted plant biomass as a high-temperature comparison (21).…”
Section: Abundancesmentioning
confidence: 99%
“…We analyzed PAHs within the same DCM extracts of Ryugu as those previous studies ( 22 , 30 ) using gas chromatography coupled with Orbitrap mass spectrometry (GC-Orbitrap) ( 31 ). We measured the δ 13 C VPDB values of the five PAHs previously identified in Hayabusa2 sample A0106 and the δ 13 C VPDB , δD VSMOW and Δ2× 13 C values of the same five PAHs from C0107 ( 21 ).…”
Section: Isotopic Measurements Of Pah Samplesmentioning
confidence: 99%
“…Compositional measurements with mass spectrometry involve ionizing the sample molecules, which is complicated by high concentrations of background ions in the sample, such as salts. Mass spectrometers have a limited volume of ions that can be analyzed, and unwanted salt ions can effect interactions that can diminish the sensitivity and accuracy of the instrument, and reduce the ability of the mass spectrometer to detect and quantify molecules of interest (Zeichner et al., 2022). Salts can also impede the ionization of biological molecules through suppression or breakdown of the molecule during ionization (Donnelly et al., 2019; Duncan et al., 2019; Metwally et al., 2015).…”
Section: Introductionmentioning
confidence: 99%