2009
DOI: 10.1109/tasc.2009.2018508
|View full text |Cite
|
Sign up to set email alerts
|

Methods, Accuracy and Reliability of ITER Conductor Tests in SULTAN

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
30
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 50 publications
(31 citation statements)
references
References 7 publications
1
30
0
Order By: Relevance
“…Samples were driven with currents going from 0 to 68 kA repeatedly, and at specified cycles ( , 200, 400, 600, 800, and 1000), a run was performed. The early voltages and/or the voltage slopes [9] are small enough to ignore the linear correction described in [4]. The offsets of all voltage tap arrays of each leg were within 1 at 68 kA.…”
Section: Test Results and Analysesmentioning
confidence: 99%
See 1 more Smart Citation
“…Samples were driven with currents going from 0 to 68 kA repeatedly, and at specified cycles ( , 200, 400, 600, 800, and 1000), a run was performed. The early voltages and/or the voltage slopes [9] are small enough to ignore the linear correction described in [4]. The offsets of all voltage tap arrays of each leg were within 1 at 68 kA.…”
Section: Test Results and Analysesmentioning
confidence: 99%
“…Two legs were assembled and an array of voltage taps and temperature sensors were attached. Joints and terminals were fabricated according to a solder filled procedure [9], which allows independent control of the helium inlet temperature in each of the two legs. Fig.…”
Section: Heat Treatment Sample Assembly and Instrumentationmentioning
confidence: 99%
“…The other three samples (JATF1, JATF3 and USTF1) were delivered to CRPP ready for test in SUL-TAN. The instrumentation of the samples evolved to very high level of complexity [16]. Two samples (TFPRO2 and JATF2) were tested twice, with enhanced instrumentation in the second campaign.…”
Section: Description Of the Iter Tf Prototype Conductorsmentioning
confidence: 99%
“…An accurate measurement of the current sharing power by gas flow calorimetry has been used to benchmark the voltage post-processing procedure and is now integral part of the T cs assessment method [8,16].…”
Section: Experimental Issuesmentioning
confidence: 99%
“…The adoption since beginning of 2007 of a new mounting procedure of the Cernox TM thermometers, aiming at maximizing the thermal coupling of the sensors with the conductor jacket, reduced the variations between measurements in same conditions down to ±10 mK [8].…”
Section: Instrumentation Accuracy and Compensationmentioning
confidence: 99%