2013
DOI: 10.1121/1.4816578
|View full text |Cite
|
Sign up to set email alerts
|

Methodology and results of calibration of tonal click detectors for small odontocetes (C-PODs)

Abstract: Static acoustic monitoring (SAM) is one major technology for observing small cetacean species. Automatic click loggers deployed for long time periods (>2 months) with a single hydrophone are a standard solution. Acoustic properties, like detection thresholds of these instruments, are essential for interpretation of results, but have nevertheless received little attention. A methodology for calibrating tonal click detectors in small tanks consisting of the determination of the horizontal directivity pattern and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
26
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(26 citation statements)
references
References 23 publications
0
26
0
Order By: Relevance
“…The C-POD is a stationary autonomous data logger designed to passively detect cetacean echolocation clicks within the frequency range 20-170 kHz (www.chelonia.co.uk) and has been used in numerous studies on harbour porpoise distribution (e.g. Dähne et al, 2013a;Hardy et al, 2012). The C-POD uses online digital waveform characterization to register click events and their time of occurrence, intensity, envelope centre frequency and bandwidth.…”
Section: Static Acoustic Monitoringmentioning
confidence: 99%
“…The C-POD is a stationary autonomous data logger designed to passively detect cetacean echolocation clicks within the frequency range 20-170 kHz (www.chelonia.co.uk) and has been used in numerous studies on harbour porpoise distribution (e.g. Dähne et al, 2013a;Hardy et al, 2012). The C-POD uses online digital waveform characterization to register click events and their time of occurrence, intensity, envelope centre frequency and bandwidth.…”
Section: Static Acoustic Monitoringmentioning
confidence: 99%
“…Carstensen et al 2006) and also to quantify displacement of porpoises by pile-driving noise , Brandt et al 2011, Dähne et al 2013a). Individual C-PODs were calibrated prior to first deployment (Dähne et al 2013b). Standard settings provided by the manufacturer were used, and off-line analysis was performed with the KERNO classifier (C-POD.exe version 2.043).…”
Section: Stationary Acoustic Monitoringmentioning
confidence: 99%
“…This equipment has been extensively used in field studies (Verfuss et al, 2007;Philpott et al, 2007;Todd et al, 2009;Dahne et al, 2013). T-POD and C-POD are efficient systems for long-term fixed operations.…”
Section: Introductionmentioning
confidence: 99%