2020
DOI: 10.1016/j.talanta.2020.120724
|View full text |Cite
|
Sign up to set email alerts
|

Methodological aspects of methylphosphonic acid analysis: Determination in river and coastal water samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(10 citation statements)
references
References 35 publications
0
8
0
Order By: Relevance
“…In this case, the application to seawater is largely restricted, as sea salt will bind to the binding sites of the SPE resin, avoiding efficient retention of the target analyte onto the column. In this regard, it has recently been shown that electrodialysis (ED) is a promising sample processing tool for the targeted analysis of pollutants from seawater (Wirth et al 2019(Wirth et al , 2021Lohrer et al 2020). ED is established in many industrial processes, e.g., for seawater desalination during drinking water production, but has found limited application in environmental sciences, so far.…”
Section: Methods For Seawater Sample Processingmentioning
confidence: 99%
“…In this case, the application to seawater is largely restricted, as sea salt will bind to the binding sites of the SPE resin, avoiding efficient retention of the target analyte onto the column. In this regard, it has recently been shown that electrodialysis (ED) is a promising sample processing tool for the targeted analysis of pollutants from seawater (Wirth et al 2019(Wirth et al , 2021Lohrer et al 2020). ED is established in many industrial processes, e.g., for seawater desalination during drinking water production, but has found limited application in environmental sciences, so far.…”
Section: Methods For Seawater Sample Processingmentioning
confidence: 99%
“…The herein further developed method mainly builds on our previous work, in which we processed water samples through weak anion-exchange solid phase extraction (SPE) with subsequent derivatization to enable analysis through GC-MS. However, Lohrer et al .…”
Section: Resultsmentioning
confidence: 99%
“…Validation of the method was conducted for MPn and 13 C-MPn concentrations, which we expected for the field based on our previous work of Lohrer et al and which we applied in the incubation samples in this study. Overall, the validation analysis revealed a precision for MPn and 13 C-MPn analysis ranging from about 3 to 20 and 0.1 to 6% and an accuracy ranging from about 3 to 23 and 4 to 30% (Table S6).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations