2013
DOI: 10.1007/s10068-013-0252-0
|View full text |Cite
|
Sign up to set email alerts
|

Method validation of 16 types of structural amino acids using an automated amino acid analyzer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
11
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(13 citation statements)
references
References 26 publications
1
11
0
Order By: Relevance
“…LOD values ranged from 0.06 g kg -1 to 0.72 g kg -1 (Table 1). Similar LOD values were obtained by Jajić et al [5] during an analysis of 14 AAs in feeds with HPLC method (0.02 g kg -1 to 1.30 g kg -1 ) and by Shim et al [11] (0.07 g kg -1 to 0.59 g kg -1 ) analysing 16 AAs in infant formula by UPLC method using AQC for pre-column derivatization. The precision of AAs measurement (repeatability and within-laboratory reproducibility) in investigated rye, pork haemoglobin and feed mixture samples was evaluated using relative standard deviation of replicated measurements (n = 10).…”
Section: Resultssupporting
confidence: 82%
See 1 more Smart Citation
“…LOD values ranged from 0.06 g kg -1 to 0.72 g kg -1 (Table 1). Similar LOD values were obtained by Jajić et al [5] during an analysis of 14 AAs in feeds with HPLC method (0.02 g kg -1 to 1.30 g kg -1 ) and by Shim et al [11] (0.07 g kg -1 to 0.59 g kg -1 ) analysing 16 AAs in infant formula by UPLC method using AQC for pre-column derivatization. The precision of AAs measurement (repeatability and within-laboratory reproducibility) in investigated rye, pork haemoglobin and feed mixture samples was evaluated using relative standard deviation of replicated measurements (n = 10).…”
Section: Resultssupporting
confidence: 82%
“…3. Good chromatographic separation was obtained for all AAs, including sulphur AAs, which is an advantage of proposed procedure, as not all sulphur AAs and secondary AAs were determined with the use of pre-column derivatization [5,11]. The validation of analytical procedure for determination of AAs in rye, pork haemoglobin and feed mixture samples converted determination of all parameters required in the feed control area.…”
Section: Resultsmentioning
confidence: 94%
“…The automated amino acid analyzer was validated using standards. The limits of detection and limits of quantification were less than 0.059 and 0.198 mg g -1 , respectively (Shim et al 2013).…”
Section: Methodsmentioning
confidence: 96%
“…The sugar content of STPH was determined by the phenol/sulfonic acid method (Masuko et al ., ). The amino acid composition was analysed with the use of an amino acid analyser (L‐8900, Hitachi, Japan) according to the method previously described by Shim et al (). The total lipids were estimated according to the method of Folch et al ().…”
Section: Methodsmentioning
confidence: 99%