2013
DOI: 10.1016/j.ymeth.2013.04.015
|View full text |Cite
|
Sign up to set email alerts
|

Method for fabrication and verification of conjugated nanoparticle-antibody tuning elements for multiplexed electrochemical biosensors

Abstract: There is a critical need for more accurate, highly sensitive and specific assay for disease diagnosis and management. A novel, multiplexed, single sensor using rapid and label free electrochemical impedance spectroscopy tuning method has been developed. The key challenges while monitoring multiple targets is frequency overlap. Here we describe the methods to circumvent the overlap, tune by use of nanoparticle (NP) and discuss the various fabrication and characterization methods to develop this technique. First… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2013
2013
2017
2017

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 44 publications
0
8
0
Order By: Relevance
“…Functionalization The process of preparing the GDE can be found in La Belle et al, 2013 and is illustrated in scheme 1, but is briefly described here: the GDE is cleaned using Al 2 O 3 polishing pads and sonicated in DI water for 20 mins, then the alkane-thiol self-assembling monolayer (1 mM 16-MHDA dissolved in ethanol) is incubated on the GDE surface for 1 hr. Next, a 10 mM EDC/80 mM NHS in PBS solution is placed on the GDE surface for 1 hr to prepare the carboxyl end of the 16-MHDA for protein attachment.…”
Section: 3mentioning
confidence: 99%
“…Functionalization The process of preparing the GDE can be found in La Belle et al, 2013 and is illustrated in scheme 1, but is briefly described here: the GDE is cleaned using Al 2 O 3 polishing pads and sonicated in DI water for 20 mins, then the alkane-thiol self-assembling monolayer (1 mM 16-MHDA dissolved in ethanol) is incubated on the GDE surface for 1 hr. Next, a 10 mM EDC/80 mM NHS in PBS solution is placed on the GDE surface for 1 hr to prepare the carboxyl end of the 16-MHDA for protein attachment.…”
Section: 3mentioning
confidence: 99%
“…In addition, just PCR technology can experience false positive readings between 9 and 57% [11] and ultimately not meet the criteria of the WHO of being specific and sensitive. Electrochemical detection offers greater sensitivity of target at low concentration [18][19][20][21][22][23]. The combination of immobilizing the TP to the surface GDE has provided evidence of achieving the specifications of the WHO ASSURED criteria and stands as an important method of future point-of-care technology.…”
Section: Resultsmentioning
confidence: 99%
“…The electron transfer resistance can be used to derive a calibration curve linking back to input concentration. 25,29 However, recently some researchers have demonstrated the use of a modified Randles circuit that implements a constant phase element (CPE) to model the capacitance. 20,23,30 CPE is commonly referred to as either a leaky or imperfect parallel plate capacitor (IPPC).…”
Section: Circuit Analysismentioning