2018
DOI: 10.1080/00032719.2017.1375510
|View full text |Cite
|
Sign up to set email alerts
|

Method Development and Quantitative Elemental Analysis ofMentha LongifoliaL. Leaves from Saudi Arabia by Total Reflection X-Ray Fluorescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…This is because the extraction process was carried out at a maximum temperature of 100°C. Based on our previous work, elemental analysis (including Br) of the leaves of the M. longifolia samples has been quantified, and the present essential oils samples have been extracted from the same M. longifolia leave samples. A comparison between the elemental concentrations in the leaves of M. longifolia samples and that found in the extracted essential oil was carried out.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…This is because the extraction process was carried out at a maximum temperature of 100°C. Based on our previous work, elemental analysis (including Br) of the leaves of the M. longifolia samples has been quantified, and the present essential oils samples have been extracted from the same M. longifolia leave samples. A comparison between the elemental concentrations in the leaves of M. longifolia samples and that found in the extracted essential oil was carried out.…”
Section: Resultsmentioning
confidence: 99%
“…Afterward, the extracted essential oils were reserved in the brown glasses and kept in −20°C refrigerator until further chemical investigation. In order to stabilize the extracted essential oil samples on the quartz reflector, 5 μl of silicone solution was deposited centrally and dried before the deposition of the oil samples …”
Section: Methodsmentioning
confidence: 99%
“…Yuan et al 251 isotope ratios was demonstrated by multiple spot analyses by LA-MC-ICP-MS. External precisions were <0.026% for 207 Pb/ 206 Pb and 208 Pb/ 206 Pb and <0.057% for 206 Pb/ 204 Pb, 207 Pb/ 204 Pb and 208 Pb/ 204 Pb (2RSD). The precision for 34 S/ 32 S (2SD) was <0.41%.…”
Section: X-ray Spectrometrymentioning
confidence: 96%
“…The performance of silicone-coated silicon reflectors was superior 206 to that of reflectors coated with poly(vinyl alcohol) for the TXRFS analysis of plant materials. Digests (HNO 3 -H 2 O 2 ) of Mentha longifolia L. leaves collected from different cities in Saudi Arabia were applied to the reflectors and 15 elements quantified.…”
Section: X-ray Spectrometrymentioning
confidence: 99%
See 1 more Smart Citation