“…External heat transfer calculations according to Mears criterion referred to some degree of film over-heating which was considered tolerable for the reactor modelling purposes. Comparable results were achieved in the PhD work of Belimov for methanation of CO/CO 2 mixtures, which has an even higher reaction rate and exothermicity degree [33]. Therefore, the conditions (i.e.…”