2013
DOI: 10.1016/j.energy.2013.06.059
|View full text |Cite
|
Sign up to set email alerts
|

Methane decomposition under a corona discharge to generate CO -free hydrogen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(9 citation statements)
references
References 57 publications
0
9
0
Order By: Relevance
“…Aleknaviciute et al [110] worked on CH4reforming to H2 at atmospheric pressure and in presence of Ar (CH4:Ar=1:1). They studied a pin-to-plate plasma configuration under corona regime.…”
Section: Corona and Sparkmentioning
confidence: 99%
See 1 more Smart Citation
“…Aleknaviciute et al [110] worked on CH4reforming to H2 at atmospheric pressure and in presence of Ar (CH4:Ar=1:1). They studied a pin-to-plate plasma configuration under corona regime.…”
Section: Corona and Sparkmentioning
confidence: 99%
“…Moreover, they observed that bigger discharge gaps favour H2 production. The effect of discharge gap had also been previously studied but a different interpretation is given in Aleknaviciute et al [110]; specifically, whilst most of the researchers claimed that the reason of CH4 conversion increase when increasing the discharge gap at constant flow rate is the longer residence time, Aleknaviciute et al [110] supported Kado's [111] explanation, according to which the breakdown voltage is affected by the discharge gap and the breakdown voltage is the dominant factor rather than the residence time. Particularly, they claimed that the higher breakdown voltage, which is needed as the gap length increases, shifts the electrons energy distribution to higher energy values, which…”
Section: Corona and Sparkmentioning
confidence: 99%
“…The literature confirms that inclusion of a small amount of oxygen in the reactive stream suppresses the formation of carbon deposits in similar processes. 28 As illustrated below in Figure 5, after adding 10 mol % air in the reactive stream, the glow discharge can steadily last for at least 120 min as indicated by the lighter yellow section of the orange bar, and the yield toward C 2+ products and lower heating value (LHV) energy efficiency are still kept at the same level.…”
Section: Resultsmentioning
confidence: 97%
“…A corona-based plasma reforming unit has been used to convert methane and propane into CO x -free hydrogen [41,42]. Argon was used to provide additional electrons and photons for higher reaction rates.…”
Section: Corona Dischargementioning
confidence: 99%