2015
DOI: 10.1007/s00590-015-1639-9
|View full text |Cite
|
Sign up to set email alerts
|

Metaphyseal tibial level (MTL) screws: a modified percutaneous technique for lateral plateau depression fractures

Abstract: The combination of subchondral screws in a jail technique with a bioabsorbable interference screw that we named metaphyseal tibia level (MTL) screw technique is, to our knowledge, not described. The MTL screw promises to be a true percutaneous reduction and fixation technique for Schatzker II and III fractures in patients with reasonable bone quality.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(11 citation statements)
references
References 18 publications
0
11
0
Order By: Relevance
“…[3][4][5][6] We propose that the common unifying principle behind many of these techniques is the provision of mechanical support close to the joint linea variable that can be quantified as the 'SJD'. 1,2 Numerous techniques have been described as a means of overcoming this problem, with the most readily available and cost effective being the 'strategic' positioning of implants such as the use of mini-fragment rim plates, peri-articular K wires, 'jail screws', 'MTL screws' and 'magic screws'.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[3][4][5][6] We propose that the common unifying principle behind many of these techniques is the provision of mechanical support close to the joint linea variable that can be quantified as the 'SJD'. 1,2 Numerous techniques have been described as a means of overcoming this problem, with the most readily available and cost effective being the 'strategic' positioning of implants such as the use of mini-fragment rim plates, peri-articular K wires, 'jail screws', 'MTL screws' and 'magic screws'.…”
Section: Discussionmentioning
confidence: 99%
“…1,2 Numerous techniques have been described as a means of overcoming this problem, with the most readily available and cost effective being the 'strategic' positioning of implants such as the use of mini-fragment rim plates, peri-articular K wires, 'jail screws', 'MTL screws' and 'magic screws'. [3][4][5][6] We propose that the common unifying principle behind many of these techniques is the provision of mechanical support close to the joint linea variable that can be quantified as the 'SJD'.…”
Section: Discussionmentioning
confidence: 99%
“…As reflected from the preoperative CT scans, medial tibia plating to fix the posterolateral corner of tibia plateau was not ideal as the screw purchase is poor. 2 We believed that the posterolateral tibial plateau fracture, particularly with a small fracture fragment, is unique in surgical planning and execution with regard to its special anatomical considerations. We needed to minimise the risk of damaging the fibular nerve as the fracture was exactly medial and in close proximity to the fibular head region.…”
Section: Discussionmentioning
confidence: 99%
“…It was important to have a good aiming device that could provide a good trajectory and avoid perforating the posterolateral corner and avoid fibular structures. 2 Besides, we had to find ways to achieve good implant bone purchase, stable fixation, a safe metaphyseal corridor for instrumental manual elevation of the depressed bone fragment, and allow adequate bone substitute impaction to maintain the reduction. 1 These considerations are especially important in osteoporotic patients.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation