2004
DOI: 10.1016/j.aca.2003.11.056
|View full text |Cite
|
Sign up to set email alerts
|

Metallo-tetraazaporphyrin based anion sensors: regulation of sensor characteristics through central metal ion coordination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
67
0
1

Year Published

2010
2010
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 237 publications
(69 citation statements)
references
References 35 publications
1
67
0
1
Order By: Relevance
“…Analytical methods based on potentiometric detection with ion-selective electrodes (ISEs) can be considered as an advantageous alternative because they are eco-friendly techniques, provide easy construction and manipulation, present good selectivity in a wide concentration range, a relatively low detection limit, show fast response and perform non-destructive analysis. This has led to increasing interest by our research group in the development and application of an ion-selective electrode using various cyclic and acyclic neutrals and ion-pairs for the determination of metal [16][17][18][19][20][21] and non-metal ions [22][23], organic molecules [24] and some selective drugs [25][26][27][28][29][30][31][32]. With this intent, we synthesized an NaTPB- …”
Section: Introductionmentioning
confidence: 99%
“…Analytical methods based on potentiometric detection with ion-selective electrodes (ISEs) can be considered as an advantageous alternative because they are eco-friendly techniques, provide easy construction and manipulation, present good selectivity in a wide concentration range, a relatively low detection limit, show fast response and perform non-destructive analysis. This has led to increasing interest by our research group in the development and application of an ion-selective electrode using various cyclic and acyclic neutrals and ion-pairs for the determination of metal [16][17][18][19][20][21] and non-metal ions [22][23], organic molecules [24] and some selective drugs [25][26][27][28][29][30][31][32]. With this intent, we synthesized an NaTPB- …”
Section: Introductionmentioning
confidence: 99%
“…Then, the sensor is used in contact with a solution containing a primary ion. 19,20 Ionophores containing nitrogen atoms such as dithizone, 21 4-(2-pyridylazo)resorcinol (PAR), 22 zincon, 23 2-(2-hydroxy-5-chloro)benzaldehyde-[4-(3-methyl-3-mesitylcyclobutyl)-1,3-thiazol-2yl] hydrazine, 24 have been widely applied in the development of optodes. In this research, the application of synthesized 5-Br salophen as ionophore in PVC membrane containing plasticizer for the sensitive determination of zinc(II) ion in aqueous solutions was investigated.…”
Section: Introductionmentioning
confidence: 99%
“…Then, the sensor is used in contact with a solution containing a primary ion. 19,20 Ionophores containing nitrogen atoms such as dithizone, 21 4-(2-pyridylazo)resorcinol (PAR), 22 zincon, 24 have Alian et al 529 Vol. 29, No.…”
mentioning
confidence: 99%
“…Sensing analysis technology has attracted significant focus because of the advantages including capability of visualization, easy operational procedure, rapid response time, cost effective equipment, convenience afforded due to the lack of need for expensive instruments and complex operation steps, high sensitivity and selectivity. [8][9][10][11][12][13][14][15][16][17][18][19][20][21] , The technology has been applied for the determination of medicine, [22][23][24][25] biomolecules, [26][27][28][29] TNP, 30 metal ions, [31][32][33][34][35][36][37][38][39][40][41][42][43][44][45][46][47][48][49][50] anions, 51 and so on. 52 Fluorescent sensors, as an important sensing analysis method, have also attracted received considerable attention for visual detection of metal ions.…”
Section: Introductionmentioning
confidence: 99%