2022
DOI: 10.1016/j.apgeochem.2022.105242
|View full text |Cite
|
Sign up to set email alerts
|

Metal (Fe, Cu, and As) transformation and association within secondary minerals in neutralized acid mine drainage characterized using X-ray absorption spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 34 publications
(14 citation statements)
references
References 59 publications
2
12
0
Order By: Relevance
“…The fitting was employed to obtain the CNs, Δ E 0 , f , σ 2 , Δ R , and goodness of fit ( R -factor). Detailed methods with respect to sample preparation, beamline instrumentation and setup, and methods of data collection and fitting results evaluation are provided in the SI and previous studies. , …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The fitting was employed to obtain the CNs, Δ E 0 , f , σ 2 , Δ R , and goodness of fit ( R -factor). Detailed methods with respect to sample preparation, beamline instrumentation and setup, and methods of data collection and fitting results evaluation are provided in the SI and previous studies. , …”
Section: Methodsmentioning
confidence: 99%
“…Detailed methods with respect to sample preparation, beamline instrumentation and setup, and methods of data collection and fitting results evaluation are provided in the SI and previous studies. 36,37 Sb Isotope Analysis by MC-ICP-MS. Sb isotope samples were collected during the kinetic, isothermal, and adsorption edge experiments and subjected to isotope separation and purification methods mainly based on previous reports. 20 Ion exchange chromatography combined with a thiol resin column was used for the separation and purification of Sb isotopes.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…The E0 of the reference minerals involved in the fitting was set to 7128 eV. More details are provided in our previous study. , …”
Section: Methodsmentioning
confidence: 99%
“…More details are provided in our previous study. 26,27 Fortran-based HAMA code was used for the wavelet transform (WT) analysis of k 3 -weighted EXAFS spectra; the details are given in Text S6. We selected data between R + ΔR (Fe) = 2.0 and 4.0 Å for qualitative research and adjusted the resolution of the signal by changing the values of parameters n and σ to distinguish the contributions of different atoms at different positions.…”
Section: Exafs Experiments and Datamentioning
confidence: 99%
“…Three to six scans were performed for each sample. The detailed description of XAFS analysis was reported previously; , a summary is also provided in Section S1 of Supporting Information.…”
Section: Materials and Methodsmentioning
confidence: 99%