2017
DOI: 10.1016/j.bios.2016.08.065
|View full text |Cite
|
Sign up to set email alerts
|

Metal-coated microfluidic channels: An approach to eliminate streaming potential effects in nano biosensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 41 publications
0
12
0
Order By: Relevance
“…These nanobiosensors offer significant improvements in selectivity, speed and sensitivity compared to traditional chemical and biological methods. Nanosensors can be used for determination of microbes or pathogens, contaminants and food freshness (Joyner and Kumar 2015; Bazin et al 2017;Bhat et al 2017;Kurbanoglu et al 2017;Lee et al 2017;Ray et al 2017). A detection technique that takes less time and that can give results within a few hours, that is simple, portable and accurate and does not require any complicated technique for operation so that even a simple farmer can use the portable system.…”
Section: Nanobiosensorsmentioning
confidence: 99%
“…These nanobiosensors offer significant improvements in selectivity, speed and sensitivity compared to traditional chemical and biological methods. Nanosensors can be used for determination of microbes or pathogens, contaminants and food freshness (Joyner and Kumar 2015; Bazin et al 2017;Bhat et al 2017;Kurbanoglu et al 2017;Lee et al 2017;Ray et al 2017). A detection technique that takes less time and that can give results within a few hours, that is simple, portable and accurate and does not require any complicated technique for operation so that even a simple farmer can use the portable system.…”
Section: Nanobiosensorsmentioning
confidence: 99%
“…When the Au surfaces are modified with AUT and MDA, the droplet charges increase. Metal‐coated microfluidic channels can be used to suppress the streaming potential and eliminate the noise of the biosensor due to the low‐stream potential of metals. The zeta potential of different substrates was investigated.…”
Section: Resultsmentioning
confidence: 99%
“…Panel C shows the statistical analysis of all local minima and maxima that correspond to the droplets at any fixed concentrations of the reactants. In order to eliminate the effect of the streaming potential, solutions can be found elsewhere in the literature [51]. In our case, the quantitative subtraction of the effect was the solution.…”
Section: Fet Monitoring Of β-Galactosidase Assaymentioning
confidence: 99%