1998
DOI: 10.1016/s0003-2670(98)00062-2
|View full text |Cite
|
Sign up to set email alerts
|

Membrane sensors for the selective determination of fluorouracil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
22
0

Year Published

2000
2000
2012
2012

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(22 citation statements)
references
References 9 publications
0
22
0
Order By: Relevance
“…The response time of the ketoconazoleselective electrode was investigated. [20][21][22] Stable responses were achieved within 30 -60 s for concentrations of 10 -3 -10 -6 mol dm -3 . The electrode exhibited a day-to-day reproducibility of about ±1.5 mV for the same ketoconazole solutions for 4 weeks after preparation.…”
Section: Resultsmentioning
confidence: 90%
See 1 more Smart Citation
“…The response time of the ketoconazoleselective electrode was investigated. [20][21][22] Stable responses were achieved within 30 -60 s for concentrations of 10 -3 -10 -6 mol dm -3 . The electrode exhibited a day-to-day reproducibility of about ±1.5 mV for the same ketoconazole solutions for 4 weeks after preparation.…”
Section: Resultsmentioning
confidence: 90%
“…These make ISE potentiometry very attractive for pharmaceutical analysis. [20][21][22] In this paper, we describe a simple potentiometric PVC-membrane sensor for the determination of ketoconazole in pharmaceutical preparations and in biological matrices. The membrane used in this electrode was made from liquid-plasticized PVC and was based on a water-insoluble ketoconazole-tetraphenylborate ion pair as an ion-exchanger.…”
mentioning
confidence: 99%
“…Applications to the determination of mercury in hazardous wastes are demonstrated; the results compare favorably with data obtained with cold vapor atomic absorption spectrometry. Silver ions, which seriously interfere with many suggested sensors, 9,10,16,20,21 have little influence on the response of the proposed sensors and the effect of lead ions can be avoided by addition of sulfate ions prior to analysis. …”
Section: Discussionmentioning
confidence: 99%
“…Indirect measurements of mercury with a solid-state membrane sensor involve exchange reactions with copper and silver dithiooxamide and diethyldithiocarbamate followed by measurements of the displaced silver and copper ions with Ag2S and Ag2S/CuS membrane sensors, respectively. 10 The use of PVC matrix membrane sensors for Hg 2+ has received much attention. Many sensing agents have been described, including calixarene derivatives containing thiazole azo group, 11 salicylaldehyde thiosemicarbazone, 12 Schiff's bases, 13 ethyl-2-benzoyl-2-phenylcarbamoyl acetate, 14 2-mercapto-benzothiazole or hexathiacyclooctadecane, 15 dibenzodiazathia-18-crown-6 dione, 16 substituted aza crown ionophores, 17 hexathia-18-crown-6 tetrone, 18 1,3-diphenylthiourea, 19 tetrathia-diazacyclotetradeca-2,9-diene, 20 substituted diaza crown ethers, 21 and p-tert-butyl calix-4-crowns with imine units.…”
Section: Introductionmentioning
confidence: 99%
“…[8][9][10] The increasing use of ion sensors in the fields of environmental, agriculture, industrial and medicinal analysis is putting more and more pressure on analytical chemists to develop new sensors for fast, accurate, reproducible and selective determination of various species. Lead is a trace heavy metal of major interest in environmental protection owing to its cumulative toxicity.…”
Section: Introductionmentioning
confidence: 99%