2007
DOI: 10.1016/j.jqsrt.2006.05.011
|View full text |Cite
|
Sign up to set email alerts
|

Medium resolution transmission measurements of at high temperature—an update

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 53 publications
(17 citation statements)
references
References 4 publications
0
17
0
Order By: Relevance
“…These can be attributed to the missing of hot lines in the HITRAN databases. Bharadwaj and Modest [53] compared the medium resolution transmissivities of CO 2 predicted by CDSD and HITEMP1995 with their experimental measurements and showed that results of the CDSD database were in better agreement with the measured data than those from HITEMP1995. Traditionally, the CDSD database for CO 2 had been more accurate than the HITRAN and HITEMP database prior to the availability of HITEMP2010.…”
Section: Isothermal and Homogeneous Co 2 (Case 2)mentioning
confidence: 97%
“…These can be attributed to the missing of hot lines in the HITRAN databases. Bharadwaj and Modest [53] compared the medium resolution transmissivities of CO 2 predicted by CDSD and HITEMP1995 with their experimental measurements and showed that results of the CDSD database were in better agreement with the measured data than those from HITEMP1995. Traditionally, the CDSD database for CO 2 had been more accurate than the HITRAN and HITEMP database prior to the availability of HITEMP2010.…”
Section: Isothermal and Homogeneous Co 2 (Case 2)mentioning
confidence: 97%
“…Table 1 Comparison of inverse calculation results using Fateev and Clausen's transmissivity spectra [14] at fine and medium-to-coarse resolutions for CO 2 at 1000 K and concentration at 0.1. Table 2 Inverse calculation results using Bharadwaj and Modest's transmissivity spectra [12,13] for CO 2 at 600 K.…”
Section: Validation For Convolution Of Convolutionmentioning
confidence: 99%
“…In the updated HITEMP 2010 CO 2 parameters were calculated from CDSD-1000 [11]. The database was extensively tested against measured medium-resolution spectra of CO 2 [12,13] for the 15, 4.3, 2.7, and 2:0 μm bands at temperatures of 300, 600, 1000, 1300, and 1550 K and measured high-resolution spectra of CO 2 in the 15, 4.3 and 2:7 μm bands at temperatures up to 1773 K [14]. The database was also tested against measured medium-resolution spectra of H 2 O [15] for the 6.3, 2.7 and 1:8 μm bands at temperatures of 600, 1000, and 1550 K and measured high-resolution spectra of H 2 O in the 2.7 and 1:8 μm bands at temperatures up to 1673 K [16].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations