Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
1993
DOI: 10.1016/0022-0728(93)80529-q
|View full text |Cite
|
Sign up to set email alerts
|

Mediated electrocatalysis at a biocatalyst electrode based on a bacterium, Gluconobacter industrius

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
31
0

Year Published

1995
1995
2016
2016

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(31 citation statements)
references
References 14 publications
0
31
0
Order By: Relevance
“…Takayama et al [23] demonstrated mediated electrocatalysis based on the bacterium Gluconobacter industrius. It was shown that the bioelectrocatalytic behavior of the Gluconobacter industrius-BQ-electrode system is very similar to that observed with a glucose oxidase-BQ-electrode system.…”
Section: Microbial Metabolism-based Biosensorsmentioning
confidence: 99%
“…Takayama et al [23] demonstrated mediated electrocatalysis based on the bacterium Gluconobacter industrius. It was shown that the bioelectrocatalytic behavior of the Gluconobacter industrius-BQ-electrode system is very similar to that observed with a glucose oxidase-BQ-electrode system.…”
Section: Microbial Metabolism-based Biosensorsmentioning
confidence: 99%
“…It should be noted that among the microbial carbohydrate analyzers there is rather large amount of mediator sensors. Besides of the sensor mentioned in (Tkac et al, 2000) the examples include the sensor based on G. oxydans and carbon paste electrode (Takayama et al, 1993), the glucose sensor based on E. coli cells and carbon paste electrode modified by benzoquinone and PQQ (Ito et al, 2002) and the glucose biosensor based on Aspergillus niger and carbon paste electrode. The ferricyanide and ferrocene were utilized as the mediators.…”
Section: Analytes and Application Of Microbial Biosensors 41 Determimentioning
confidence: 99%
“…Working electrode was formed according to the methods described in [19] by filling a 1-mL plastic syringe with prepared carbon paste. Carbon paste was prepared by mixing 100 mg of graphite powder and 50 mL of mineral oil with required amount of mediator.…”
Section: Preparation Of the Electrode Modified With Bacterial Whole Cmentioning
confidence: 99%
“…For tight holding, the cells on the electrode were covered with a dialysis membrane [19]. Dialysis membrane (cut off 14 000) was purchased from Sigma (Germany).…”
mentioning
confidence: 99%