Reviews of Physiology, Biochemistry and Pharmacology
DOI: 10.1007/bfb0004985
|View full text |Cite
|
Sign up to set email alerts
|

Mechanosensitive ion channels in nonspecialized cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
205
0

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 237 publications
(208 citation statements)
references
References 216 publications
(289 reference statements)
2
205
0
Order By: Relevance
“…[61, 124,136,144,165,176,178]. Because of its trivalency, Gd 3+ will bind with high affinity to negative groups on proteins, lipids, and polysaccharides, as well as any inorganic anions present in solution [17,61].…”
Section: "Mechanopharmaceutics"mentioning
confidence: 99%
See 1 more Smart Citation
“…[61, 124,136,144,165,176,178]. Because of its trivalency, Gd 3+ will bind with high affinity to negative groups on proteins, lipids, and polysaccharides, as well as any inorganic anions present in solution [17,61].…”
Section: "Mechanopharmaceutics"mentioning
confidence: 99%
“…Although the distinction between adaptation and inactivation still needs to be made, the observation is significant because the clear absence of any CSK excludes its involvement in these transient kinetics. One possible explanation is timedependent sliding/relaxation of the two monolayers that results in relaxation of the gating tension [144]. Because it was clearly demonstrated that channels could not be reactivated without a finite time for recovery, the phenomenon was referred to as desensitization.…”
Section: Mscs and Mscl In Escherichia Colimentioning
confidence: 99%
“…Previously we demonstrated that stretch-induced SAC activation augments Na ϩ -K ϩ -ATPase activity (19). To relate plasma membrane tension to SAC activation, we employed a prevalent theory (29,41,49,50) that the probability, P o , of a SAC being open to ion traffic is determined by a Boltzmann probability distribution dependent on plasma membrane tension, T:…”
Section: Resultsmentioning
confidence: 99%
“…tension change required to cause an e-fold increase in relative channel activity. For our purposes, we performed parametric simulations over a range of values for , and T 1/2 corresponding to a range of parameter values reported in the SAC classification literature (24,29,30,41,49,50). Model-generated membrane tension was used to calculate a P o "wave" via Eq.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation