2021
DOI: 10.1002/chem.202004556
|View full text |Cite
|
Sign up to set email alerts
|

Mechanistic Investigation on Chemiluminescent Formaldehyde Probes

Abstract: Af irst-generation pair of chemiluminescentf ormaldehyde (FA) probes (CFAP540a nd CFAP700)w as reported recently.C FAP540 and CFAP700, with high selectivity and sensitivity to FA,a re, respectively,s uitable in cell and in vivo. Experimentalists have confirmed that both probes utilize a general2-aza-Cope FA-reactivet rigger and ac hemiluminogenic phenoxydioxetane scaffold. The mechanism and detailed process of CFAP chemiluminescence (CL) remainlargely unknown. In the present paper,(time-dependent) density func… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 45 publications
0
6
0
Order By: Relevance
“…Testing of the functionals and the basis sets has been performed previously [ 3 ]. This computational level has also been reasonably used in the research of several previous chemiluminescent [ 14 ] and bioluminescent [ 15 , 16 ] systems. These calculations involved optimizing the stationary points, analyzing the frequencies, and conducting an intrinsic reaction coordinate (IRC) calculation.…”
Section: Computational Model and Methodsmentioning
confidence: 99%
“…Testing of the functionals and the basis sets has been performed previously [ 3 ]. This computational level has also been reasonably used in the research of several previous chemiluminescent [ 14 ] and bioluminescent [ 15 , 16 ] systems. These calculations involved optimizing the stationary points, analyzing the frequencies, and conducting an intrinsic reaction coordinate (IRC) calculation.…”
Section: Computational Model and Methodsmentioning
confidence: 99%
“…Commonly used materials include luminophores (e. g., fluorescent dyes, fluorescent proteins), luminous substrates (e. g., oxides, sulfides), and fluorescent probes. [20]…”
Section: Diagnostic Technologiesmentioning
confidence: 99%
“…Besides the above cases, the nearly degenerate 1 (σ, σ*) and 1 (n, σ*) states in uncatazlyed CL and two crossings between the diabatic non-ET and ET states in ET-catalyzed CL were also found for many other 1,2-dioxetanes , and 1,2-dioxetanones. ,, However, these S 0 /S 1 CIs were not directly optimized due to the computational costs and difficulties. Moreover, conventional density functional theory (DFT) and linear-response (LR) time-dependent (TD) DFT (LR-TDDFT) with an open-shell reference state used by some of these studies could not correctly describe the S 0 /S 1 energy gaps due to the heavy spin-contaminations (see Appendix).…”
Section: Conical Intersectionsmentioning
confidence: 99%