2023
DOI: 10.30802/aalas-jaalas-22-000105
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical Washing Prevents Transmission of Bacterial, Viral, and Protozoal Murine Pathogens from Cages

Abstract: Infectious agents have varying susceptibilities to thermal inactivation and/or mechanical removal from cages by the use of heated, pressurized water. In this study, we tested whether 5 specific infectious organisms (Candidatus savagella [segmented filamentous bacterium (SFB)], Helicobacter sp., mouse norovirus (MNV), Tritrichomonas sp., and Entamoeba muris) could survive the cage wash process and still infect naïve mice. These 5 organisms were chosen due to their prevalence in rodent colonies, environmental st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 28 publications
0
1
0
Order By: Relevance
“…6 While many institutions autoclave IVC components between use, others depend on the effectiveness of heat and/or chemical sanitization provided by mechanical cage washing equipment. 7,32 Therefore, alternatively or in addition to the ease of horizontal transmission, could inadequate cage sanitization lead to the persistence of Cm's infective EBs on cage surfaces facilitating intercage transmission despite the use of the state-of-the-art caging and husbandry techniques? The studies described herein were devised and conducted to better understand whether either or both these mechanisms could be a factor in the spread of Cm within mouse colonies.…”
Section: Introductionmentioning
confidence: 99%
“…6 While many institutions autoclave IVC components between use, others depend on the effectiveness of heat and/or chemical sanitization provided by mechanical cage washing equipment. 7,32 Therefore, alternatively or in addition to the ease of horizontal transmission, could inadequate cage sanitization lead to the persistence of Cm's infective EBs on cage surfaces facilitating intercage transmission despite the use of the state-of-the-art caging and husbandry techniques? The studies described herein were devised and conducted to better understand whether either or both these mechanisms could be a factor in the spread of Cm within mouse colonies.…”
Section: Introductionmentioning
confidence: 99%