2005
DOI: 10.1016/j.jtcvs.2004.12.037
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical support of total cavopulmonary connection with an axial flow pump

Abstract: Axial flow pump support from the inferior vena cava to the pulmonary artery can prevent the substantial decrease of aortic flow and pressure associated with total cavopulmonary connection and can reverse its poor hemodynamics. This is a simple model that can be used to further evaluate the potential of mechanical support as a treatment option in failing Fontan circulation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
47
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(47 citation statements)
references
References 8 publications
0
47
0
Order By: Relevance
“…A new design, recently presented 21 by this team, indicates their exploration of a unique bi-conical impeller pump or disk to stabilize flow directionality in the TCPC junction. Riemer et al 19 at the Stanford University have used a sheep model of the TCPC to test the response to the Thoratec HeartMate II axial flow blood pump (Thoratec Corporation, Pleasanton, CA, USA). These studies demonstrated a baseline return of cardiac output, IVC flow, and arterial pressures.…”
Section: Discussionmentioning
confidence: 99%
“…A new design, recently presented 21 by this team, indicates their exploration of a unique bi-conical impeller pump or disk to stabilize flow directionality in the TCPC junction. Riemer et al 19 at the Stanford University have used a sheep model of the TCPC to test the response to the Thoratec HeartMate II axial flow blood pump (Thoratec Corporation, Pleasanton, CA, USA). These studies demonstrated a baseline return of cardiac output, IVC flow, and arterial pressures.…”
Section: Discussionmentioning
confidence: 99%
“…The prospect of a mechanical Fontan support device has been raised and a number of designs have undergone mathematical modeling (160,161) and animal studies. (162)(163)(164) Conflict of interest: none declared.…”
Section: Role Of Transplantationmentioning
confidence: 99%
“…· Reports of ventricular assist device use in Fontan patients are rare and in general document technical aspects of the implant, clinical improvement, and a successful bridge to transplantation [4750]. There is only one reported case using a total artificial heart in a single-ventricle Fontan patient who recovered and eventually went on to have heart transplant [51].…”
Section: Assist Devicesmentioning
confidence: 99%