2018
DOI: 10.1016/j.ijcard.2018.04.042
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical prosthetic heart valves: Quality of anticoagulation and thromboembolic risk. The observational multicenter PLECTRUM study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
28
5
4

Year Published

2019
2019
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(41 citation statements)
references
References 29 publications
4
28
5
4
Order By: Relevance
“…Among patients with atrial fibrillation, studies have shown an association between low quality of VKA treatment and the risk of outcomes, whereas studies on patients with mechanical heart valve have shown contradictory results. [8][9][10][11] This nationwide, carefully designed study set out to examine the association between TTR and the risk of thromboembolic events and bleeding in patients with mechanical valve prostheses.…”
Section: Perspectivementioning
confidence: 99%
See 1 more Smart Citation
“…Among patients with atrial fibrillation, studies have shown an association between low quality of VKA treatment and the risk of outcomes, whereas studies on patients with mechanical heart valve have shown contradictory results. [8][9][10][11] This nationwide, carefully designed study set out to examine the association between TTR and the risk of thromboembolic events and bleeding in patients with mechanical valve prostheses.…”
Section: Perspectivementioning
confidence: 99%
“…Results: In total, 659 patients undergoing mechanical heart valve replacement were included in the study. Median number of international normalized ratio measurements in the 6-month period after surgery was 13 (interquartile range, [8][9][10][11][12][13][14][15][16][17][18][19]. Median TTR was 54.9% (interquartile range, 39.0%-72.9%) and 29.1% of patients had a TTR !70%.…”
mentioning
confidence: 99%
“…Their implantation is associated with reduced quality of life. Mechanical prostheses require life-long anticoagulation therapy and are associated with a substantially high risk of bleedings [5]. Tissue heart valves are susceptible to calcification and degeneration resulting in the structural failure, requiring repeat surgery [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…A recent observational study from Italy provided some reassuring data. 2 In a cohort of more than 2350 patients in the Italian Federation of Anticoagulation Clinics, the overall rate of TE events was only 0.67 per 100 patient years. In contrast, the bleeding risk was slightly higher at 1.0 major bleeds per 100 patient years.…”
Section: Vivek Rao MD Phdmentioning
confidence: 98%