2017
DOI: 10.1016/j.joen.2017.05.025
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical Properties of Various Heat-treated Nickel-titanium Rotary Instruments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

12
63
0
5

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 87 publications
(81 citation statements)
references
References 30 publications
12
63
0
5
Order By: Relevance
“…In accordance with these findings, several studies proved that Hyflex EDM exhibits a significantly increased cyclic fatigue resistance compared with Hyflex CM, M-Wire and conventional NiTi instruments (Kaval et al 2016, Pedull a et al 2016, Pirani et al 2016, Goo et al 2017, G€ undo gar & € Ozy€ urek 2017, Iacono et al 2017. The flexibility of Hyflex EDM was found to be similar to other CM Wire instruments (Goo et al 2017, Iacono et al 2017. Hyflex EDM has been reported to create a centred root canal preparation, respecting the original root canal anatomy ( € Ozy€ urek et al 2017, Pinheiro et al 2018, Venino et al 2017).…”
Section: Electrical Discharge Machining (Hyflex Edm)mentioning
confidence: 68%
See 3 more Smart Citations
“…In accordance with these findings, several studies proved that Hyflex EDM exhibits a significantly increased cyclic fatigue resistance compared with Hyflex CM, M-Wire and conventional NiTi instruments (Kaval et al 2016, Pedull a et al 2016, Pirani et al 2016, Goo et al 2017, G€ undo gar & € Ozy€ urek 2017, Iacono et al 2017. The flexibility of Hyflex EDM was found to be similar to other CM Wire instruments (Goo et al 2017, Iacono et al 2017. Hyflex EDM has been reported to create a centred root canal preparation, respecting the original root canal anatomy ( € Ozy€ urek et al 2017, Pinheiro et al 2018, Venino et al 2017).…”
Section: Electrical Discharge Machining (Hyflex Edm)mentioning
confidence: 68%
“…CM Wire instruments have a significantly enhanced cyclic fatigue resistance compared with M-Wire and conventional NiTi instruments (Shen et al 2011b, Plotino et al 2014a, Capar et al 2015, Goo et al 2017, Soares et al 2017, AlShwaimi 2018, which might be attributed to their martensitic state. CM Wire instruments exhibited a greater angle of deflection at failure than M-Wire and conventional NiTi, but the maximum torque was nearly equal (Casper et al 2011, Peters et al 2012.…”
Section: Wirementioning
confidence: 98%
See 2 more Smart Citations
“…, Goo et al . , Duque et al . ) and concluded that the more flexible NiTi alloys favoured less canal transportation.…”
mentioning
confidence: 99%