Mechanical properties of faecal sludge

Abstract: On-site sanitation facilities contribute to the majority of toilet facilities in developing countries as full waterborne sanitation is not feasible or affordable. The characteristics of faecal sludge vary greatly between different locations and types of onsite sanitation facilities and at the same time their understanding is crucial for improvement of the existing faecal sludge management services. The Pollution Research Group (PRG), within the School of Chemical Engineering in the University of Kwa-Zulu Natal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 4 publications
(1 reference statement)
1
6
0
Order By: Relevance
“…A low methane content, approximately around 23%, along with a diminished methanogenic potential, was also noted in faecal sludge in Bobo Dioulasso, Burkina Faso, as reported by Christiane [84]. These values align closely with those reported in the literature, ranging between 45 and 50 NL CH4/KgVS for septic tank sludge [85]. On the other hand, other works have found values ranging from 0.009 m 3 to 0.028 m 3 /kg VS [27,86].…”
Section: Unitsupporting
confidence: 87%
“…A low methane content, approximately around 23%, along with a diminished methanogenic potential, was also noted in faecal sludge in Bobo Dioulasso, Burkina Faso, as reported by Christiane [84]. These values align closely with those reported in the literature, ranging between 45 and 50 NL CH4/KgVS for septic tank sludge [85]. On the other hand, other works have found values ranging from 0.009 m 3 to 0.028 m 3 /kg VS [27,86].…”
Section: Unitsupporting
confidence: 87%
“…However, most of the laboratory replicates in this study have an acceptable variation of <10%, albeit more than 5%, which is the standard for wastewater analysis (APHA, 2017). Although progress is being made on method development, standard methods and standards for laboratory error specifically for fecal sludge have not yet been established (Velkushanova et al, 2021). Precise and accurate measurements of fecal sludge are challenging, and as standards are developed, it needs to be determined what acceptable variations are.…”
Section: Laboratory Qa/qc Resultsmentioning
confidence: 99%
“…Laboratory analysis was done at the local laboratory of each of the collaborating institutions. Total solids (TS), volatile solids (VS), pH, and electrical conductivity (EC) were quantified according to Velkushanova et al (2021). In Sierra Leone, VS was not measured due to a lack of required laboratory equipment.…”
Section: Analytical Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This collectively emphasizes the feasibility and profitability of the dewatering machine investment. Ultimately, these findings support the selection of the Constant pitch screw with a tapered shaft design for the pressing screw and highlight the potential for improved dewatering and sun-drying processes in the management and utilization of biogas slurry [10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. The repayment duration in this research is computed as 1 year 10 months and 23 days, which is less than the payback period in Sherpa et al's 2017 study.…”
Section: Chapter 4: Conclusionmentioning
confidence: 88%