Mechanical Performance of the LARP Nb$_{3}$Sn Quadrupole Magnet LQS01

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 18 publications
(22 citation statements)
references
References 10 publications
(11 reference statements)
0
22
0
Order By: Relevance
“…For both series, the maximum observed dodecapole deviations from the simulated values are in the order of 1.5 units in LQS magnets and 1 unit in TQS in current range from 2 kA to 9 kA. As was discussed in [6]- [8] and [11], the larger saturation effect in these magnets is due to the iron pads placed next to the coils. If necessary, several methods to correct this saturation effect can be applied, for example: introducing holes into appropriate places in iron pads and yoke, or by substituting the iron pads with stainless ones.…”
Section: Iron Saturation Effectmentioning
confidence: 66%
See 1 more Smart Citation
“…For both series, the maximum observed dodecapole deviations from the simulated values are in the order of 1.5 units in LQS magnets and 1 unit in TQS in current range from 2 kA to 9 kA. As was discussed in [6]- [8] and [11], the larger saturation effect in these magnets is due to the iron pads placed next to the coils. If necessary, several methods to correct this saturation effect can be applied, for example: introducing holes into appropriate places in iron pads and yoke, or by substituting the iron pads with stainless ones.…”
Section: Iron Saturation Effectmentioning
confidence: 66%
“…LQS01 quadrupole performed extremely well during the quench tests, and magnetic field quality measurements were taken with two different coil pre-stresses. More information about the LQS01 production and testing is presented elsewhere [6]- [8].…”
mentioning
confidence: 99%
“…The 4 m long coil has the same cross section as the TQ coils [4][5][6][7] with one exception. The length of cable used was shorter than standard so one half-turn was removed from each Side "Ear" layer.…”
Section: Coil Design and Fabricationmentioning
confidence: 99%
“…The results are presented in FIGURE 8. For comparison, temperature dependence is also shown for the long quadrupole magnet (LQS01b) [7] with coils made of RRP 54/61 Nb 3 Sn strand and the 1m mirror TQM03. Whereas LQS01b shows a reduction of quench current at T < 3 K due to flux jump instabilities in the superconductor, LQM01 shows the expected temperature dependence in the entire temperature range from 1.9 to 4.6 K.…”
Section: Magnet Ramp Rate and Temperature Dependencementioning
confidence: 99%