2021
DOI: 10.1016/j.compstruct.2021.114320
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical performance and defect analysis of the imperfect micro smooth gyroid cylinder shell structure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…Besides these widely used AM technologies, there are many special methods to fabricate TPMS porous structures. Cao et al fabricated TPMS structures by projection micro-stereolithography (PµSL) with PEGDA [165]. The manufacturing principle and TPMS results can be seen in figure 19(a).…”
Section: Other Special Fabrication Methodsmentioning
confidence: 99%
“…Besides these widely used AM technologies, there are many special methods to fabricate TPMS porous structures. Cao et al fabricated TPMS structures by projection micro-stereolithography (PµSL) with PEGDA [165]. The manufacturing principle and TPMS results can be seen in figure 19(a).…”
Section: Other Special Fabrication Methodsmentioning
confidence: 99%
“…Based on findings in the literature, waviness in cell struts or walls, deviation of strut cross-sectional geometry, thickness variation of strut, strut detachment, rough surface due to powder particles attachment to the surface, voids between printed layers, and microporosity are the most common types of defects reported in 3D printed polymeric lattice structures [59,[73][74][75][76][77][78][79][80][81][82][83][84].…”
Section: Process-induced Defects In Additively Manufactured Structuresmentioning
confidence: 99%
“…Based on the fine element analysis, it was observed that the gyroid cylindrical lattice structure (G-CLS) shows improved energy absorption capability in comparison to CLS based on the strun unit cells. Research carried out by Cao et al for G-CLS [50] and primitive cylindrical lattice structure (P-CLS) [51] showed that geometrical defects have a significant impact on the mechanical properties, what should be taken into consideration during analyzing the deformation mode and preparing simulation models. Szatkiewcz et al [52] analyzed the mechanical properties, energy absorption capacity, and deformation models of Gyroid TPMS cylindrical structures.…”
Section: Introductionmentioning
confidence: 99%