2019
DOI: 10.1016/j.brachy.2019.06.005
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical evaluation of the Bravos afterloader system for HDR brachytherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
16
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(22 citation statements)
references
References 14 publications
2
16
0
Order By: Relevance
“…Some clinics do not accept treatment plan dwell times shorter than 0.5 s due to the time it takes for the source to move between dwell positions (transit time) [61,62]. In addition, in modern afterloaders, the minimum dwell time depends on the distance between dwell positions [63]. The aim of measuring time is to ensure that the dwell times are correct.…”
Section: Dwell Time Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Some clinics do not accept treatment plan dwell times shorter than 0.5 s due to the time it takes for the source to move between dwell positions (transit time) [61,62]. In addition, in modern afterloaders, the minimum dwell time depends on the distance between dwell positions [63]. The aim of measuring time is to ensure that the dwell times are correct.…”
Section: Dwell Time Measurementsmentioning
confidence: 99%
“…However, dwell time corrections (e.g. rescaling due to air-kerma strength, transit time and minimum dwell time) [61,63] are applied just before the treatment by the treatment console. Therefore, measurements should be compared to the plan executed by the afterloader and this information should be accessible.…”
Section: Export Of Dwell Positions and Timesmentioning
confidence: 99%
“…Afterloader QA can adopt video cameras instead of radiochromic films, allowing more precise dwell positions verification and also dwell times measurements. As an example, Varian Medical Systems (Palo Alto, CA) implemented a camera-based QA device (CamScale) to the Bravos afterloading system released in 2018 [25,26], which is not time resolved but already allows to easily perform multiple dwell position measurements and system recalibration when necessary (more on this topic in section 4.5.1). Studies have shown that the source cable movement can be measured using regular video cameras [27][28][29] and high speed cameras [25,30] .…”
Section: Advanced Treatment Workflow Methodsmentioning
confidence: 99%
“…As an example, Varian Medical Systems (Palo Alto, CA) implemented a camera-based QA device (CamScale) to the Bravos afterloading system released in 2018 [25,26], which is not time resolved but already allows to easily perform multiple dwell position measurements and system recalibration when necessary (more on this topic in section 4.5.1). Studies have shown that the source cable movement can be measured using regular video cameras [27][28][29] and high speed cameras [25,30] . Although such techniques are not practical for daily QA, the latter offers a precise and accurate method to evaluate dwell positions, dwell times and source speed profiles, which can be used to evaluate transit time dosimetry.…”
Section: Advanced Treatment Workflow Methodsmentioning
confidence: 99%
See 1 more Smart Citation