2008
DOI: 10.1007/s11340-008-9187-4
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical Characterization of Coatings Using Microbeam Bending and Digital Image Correlation Techniques

Abstract: A new technique for characterizing end-supported microbeams of coating materials is presented. Microbeams are fabricated using micro-EDM machining to isolate the material under investigation from the underlying substrate. Three-and four-point bending is realized by a custom-built microspecimen testing system, and digital image correlation is employed to capture full-field strains and displacements in theses microbeams. These experiments provide the foundation for the use of finite element modeling and inverse … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
55
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 86 publications
(56 citation statements)
references
References 18 publications
1
55
0
Order By: Relevance
“…The machine is similar to the testing apparatus used by Eberl et al [23], which was used for testing thin films. Figure 1 illustrates the frame, two linear actuators, alignment stage, load cell, safety springs, and a camera.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The machine is similar to the testing apparatus used by Eberl et al [23], which was used for testing thin films. Figure 1 illustrates the frame, two linear actuators, alignment stage, load cell, safety springs, and a camera.…”
Section: Methodsmentioning
confidence: 99%
“…The actuators control stage movement and are controlled by Matlab software. The camera was used for digital image correlation (DIC) to monitor strain [23]. Fatigue precracks (as specified in ASTM E399) were not achieved due to early fracture.…”
Section: Methodsmentioning
confidence: 99%
“…Tensile tests of individual fibers were performed in a Nova 200 scanning electron microscope/focused ion beam (SEM/FIB) equipped with a piezo-actuated platform and Femtotools load cells. Strain is calculated using a Matlab routine [48]. For more details about individual wire testing, one can refer to [49][50][51].…”
Section: Methodsmentioning
confidence: 99%
“…Stress-strain curves were created from photo collections and the time/load UTM data via Digital Image Correlation and Tracking Matlab scripts (Eberl et al 2006). Onedimensional average strains were taken in both the vertical and horizontal directions.…”
Section: Methodsmentioning
confidence: 99%