2016
DOI: 10.1016/j.jobe.2016.05.005
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical characterization and thermal conductivity measurements using of a new 'small hot-box' apparatus: innovative insulating reinforced coatings analysis

Abstract: Marco (2016) Mechanical characterization and thermal conductivity measurements using of a new 'small hot-box' apparatus: innovative insulating reinforced coatings analysis. Journal of Building Engineering, 7. pp. 63-70. ISSN 2352-7102 Published by: Elsevier URL:http://dx

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 18 publications
0
8
0
2
Order By: Relevance
“…Therefore, the literature review shows that the calibrated hot box is the most used [3,4,6,13,17,19,20,[23][24][25][26]28,30,32,33,36,37] followed by the guarded hot box [5,7,14,15,18,21,22,29,31,34,35] and the simple hot box [16,27,38]. The measuring systems always employ analog probes and the thermocouples are more widely used [3][4][5][6][13][14][15][16]18,[21][22][23][24][25][26][27]29,31,[33][34]…”
Section: Common Systems and Literature Backgroundmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, the literature review shows that the calibrated hot box is the most used [3,4,6,13,17,19,20,[23][24][25][26]28,30,32,33,36,37] followed by the guarded hot box [5,7,14,15,18,21,22,29,31,34,35] and the simple hot box [16,27,38]. The measuring systems always employ analog probes and the thermocouples are more widely used [3][4][5][6][13][14][15][16]18,[21][22][23][24][25][26][27]29,31,[33][34]…”
Section: Common Systems and Literature Backgroundmentioning
confidence: 99%
“…The measuring systems always employ analog probes and the thermocouples are more widely used [3][4][5][6][13][14][15][16]18,[21][22][23][24][25][26][27]29,31,[33][34][35][36][37][38] with respect to the thermoresistances [17,19,20,28,34]. The number of probes installed that, as mentioned, depends on the size of the hot box, is very variable: some cases have less than 20 probes [13,16,19,20,27,28,38], most cases have a number of probes between 20 and 100 [4][5][6]14,15,[23][24][25]33,36], while in three cases there are more than 100 probes [34,35,...…”
Section: Common Systems and Literature Backgroundmentioning
confidence: 99%
“…En muchos trabajos en los que se mide la conductividad térmica de materiales aislantes, el método más común es el de placa caliente guardada, establecido por la norma ASTM C 1363 [7], [8]. En estos se establece un gradiente de temperatura constante por lo cual el flujo de calor a través de la muestra se mantiene en régimen estacionario.…”
Section: Ingeniería Y Cienciaunclassified
“…Gomes et al [11] usan dos métodos para comparar sus resultados: régimen estacionario y transitorio, obteniendo diferentes resultados con ambos métodos. Buratti et al [7] desarrollaron un equipo consistente en una caja con un panel caliente y otro frío, para caracterizar materiales compuestos obteniendo valores del CT en rangos adecuados para considerarlos como aislantes térmicos prometedores en remodelación de edificios. Por su parte Jannot et al [12] presentan un método de pulso de calor para medir el CT en materiales aislantes de baja densiing.cienc., vol.…”
Section: Ingeniería Y Cienciaunclassified
“…A significant part of Europe's building heritage is made up of old buildings [1][2][3][4] constructed using poor quality insulation materials. Therefore, recent regulations, such as the EU Directive 2010/31 [5] on buildings' energy efficiency, aim to increase energy efficiency standards, by considering both the single components and the entire building.…”
Section: Introductionmentioning
confidence: 99%