Mechanical biomarkers by torsional shear ultrasound for medical diagnosis

Abstract: The WHO estimates that 15 million babies yearly (1 in 10) will be born preterm. Worldwide, complications of preterm births have supplanted pneumonia as the primary cause of child mortality [1]. The biology of cervical ripening that leads to birth is poorly understood, and there is no clinical tool to quantitatively evaluate the cervical biomechanical state, which in words of Feltovich [2]“… likely contributes to the reason the singleton spontaneous preterm birth rate has not changed appreciably in more than 10… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…The intra- and inter-day reliability of SWE described in this study (ICC = 0.62 to 0.80) was similar to what previous investigations have reported in healthy participants [ 11 , 13 ], although the CV registered in our study (CV = 15.3 to 33.8%) was higher in both measurement time comparisons [ 11 , 13 ]. SWE is based on the interpretation of the propagation of shear waves to estimate shear wave velocity (m/s) and shear modulus (kPa) [ 33 ], so factors such as depth, the anatomical structures evaluated, or the degree of stenosis could affect the results and reliability tasks [ 8 , 9 , 33 , 34 ]. The thickness of superficial connective tissue could provoke the saturation of the elastogram, which occurs when the elasticity of the tissue exceeds the upper limit of the elasticity scale that is used to render the elastogram, and would make the SWE exam of subjacent tissue difficult [ 16 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The intra- and inter-day reliability of SWE described in this study (ICC = 0.62 to 0.80) was similar to what previous investigations have reported in healthy participants [ 11 , 13 ], although the CV registered in our study (CV = 15.3 to 33.8%) was higher in both measurement time comparisons [ 11 , 13 ]. SWE is based on the interpretation of the propagation of shear waves to estimate shear wave velocity (m/s) and shear modulus (kPa) [ 33 ], so factors such as depth, the anatomical structures evaluated, or the degree of stenosis could affect the results and reliability tasks [ 8 , 9 , 33 , 34 ]. The thickness of superficial connective tissue could provoke the saturation of the elastogram, which occurs when the elasticity of the tissue exceeds the upper limit of the elasticity scale that is used to render the elastogram, and would make the SWE exam of subjacent tissue difficult [ 16 ].…”
Section: Discussionmentioning
confidence: 99%
“…Elastography ultrasound is widely used to quantify the mechanical properties of tissues [ 5 , 7 , 8 , 9 ]. There are different methods of elastography which have been applied to describe passive muscle stiffness based on the adaptation of the tissue to mechanical stimuli.…”
Section: Introductionmentioning
confidence: 99%
“…Labeled as “palpation imaging”, elastography offers qualitative and quantitative information on the tissue anatomical architecture, identifying changes in tissue stiffness [ 20 , 22 , 23 , 24 ]. Elastography has been validated as a marker of pathological states in many clinical fields by facilitating the diagnosis, differential diagnosis, and therapeutic management and establishing its role in endocrinology (thyroid and parathyroid area) [ 25 , 26 ], hepatogastroenterology [ 20 , 27 , 28 , 29 ], senology [ 30 , 31 ], urology [ 32 , 33 , 34 ], and otorhinolaryngology [ 35 ].…”
Section: Introductionmentioning
confidence: 99%
“…By analyzing the particle displacements with an ultrafast ultrasound acquisition sequence, quantitative measurements of tissue elasticity can be obtained [36]. Evaluation of the elasticity characteristics of the tissue can help in identifying special types of tissues [39] Shear wave elastography (Aixplorer Super Sonic) overlays the elastographic image on the B-mode, providing a real-time map of elasticity. The operator should also pay attention not to apply any kind of pressure on the probe [40].…”
Section: Introductionmentioning
confidence: 99%