2020
DOI: 10.1186/s12987-020-00195-3
|View full text |Cite
|
Sign up to set email alerts
|

Measuring intracranial pressure by invasive, less invasive or non-invasive means: limitations and avenues for improvement

Abstract: Sixty years have passed since neurosurgeon Nils Lundberg presented his thesis about intracranial pressure (ICP) monitoring, which represents a milestone for its clinical introduction. Monitoring of ICP has since become a clinical routine worldwide, and today represents a cornerstone in surveillance of patients with acute brain injury or disease, and a diagnostic of individuals with chronic neurological disease. There is, however, controversy regarding indications, clinical usefulness and the clinical role of t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
92
0
4

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 103 publications
(99 citation statements)
references
References 213 publications
(312 reference statements)
0
92
0
4
Order By: Relevance
“…This method was again validated initially against synthetic data before feasibility was demonstrated on two patients undergoing invasive ICP monitoring via EVD. In both patients, prediction accuracy increased after assimilating CBFV data into the model and the researchers obtained a prediction error for mean ICP of less than 2 mm Hg in each patient, within the clinically accepted standard [31,32,177]. However, significantly more work involving larger, heteregenous patient populations needs to be conducted in order to establish the efficacy of this method for ICP estimation.…”
Section: Model-based Methodsmentioning
confidence: 82%
See 3 more Smart Citations
“…This method was again validated initially against synthetic data before feasibility was demonstrated on two patients undergoing invasive ICP monitoring via EVD. In both patients, prediction accuracy increased after assimilating CBFV data into the model and the researchers obtained a prediction error for mean ICP of less than 2 mm Hg in each patient, within the clinically accepted standard [31,32,177]. However, significantly more work involving larger, heteregenous patient populations needs to be conducted in order to establish the efficacy of this method for ICP estimation.…”
Section: Model-based Methodsmentioning
confidence: 82%
“…As a result, LP is no longer recommended for use in diagnosing ICH in neurocritical care settings and is reserved more often for use in hydrocephalus and idiopathic intracranial hypertension [3,29]. Guidelines regarding the accuracy of invasive ICP measurement have been outlined by The American National Standards Institute (ANSI)/Association for the Advancement of Medical Instrumentation (AAMI) and specify that ICP in the range of 0 − 20 mm Hg should maintain an accuracy of ±2 mm Hg, while ICP > 20 mm Hg should not exceed 10% error [31,32]. The relationship between pressure and volume within the intracranial compartment.…”
Section: Invasive Icp Monitoring Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Neuroimaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI) and transcranial Doppler ultrasound allow a non-invasive diagnosis [2] [3] [4]. However, each of them has its limits [2] [5] [6]. As diagnosis alternative, optic nerve sheath diameter (ONSD) measuring, a relatively recent technique was developed [7] [8] [9].…”
Section: Introductionmentioning
confidence: 99%