1984
DOI: 10.1097/00003246-198409000-00037
|View full text |Cite
|
Sign up to set email alerts
|

Measuring gas leakage from bronchopleural fistulas during high-frequency jet ventilation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Year Published

1987
1987
2019
2019

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…This method, however, becomes increasingly inaccurate as the size of the leak decreases, particularly when it is less than 200 ml/breath [186]. More accurate, albeit cumbersome, methods have been developed to quantify the amount of flow through a BPF [187–190]. Air flows through BPFs have been reported up to 22 L/min [187].…”
Section: Pleural Effusions In the Icumentioning
confidence: 99%
See 3 more Smart Citations
“…This method, however, becomes increasingly inaccurate as the size of the leak decreases, particularly when it is less than 200 ml/breath [186]. More accurate, albeit cumbersome, methods have been developed to quantify the amount of flow through a BPF [187–190]. Air flows through BPFs have been reported up to 22 L/min [187].…”
Section: Pleural Effusions In the Icumentioning
confidence: 99%
“…More accurate, albeit cumbersome, methods have been developed to quantify the amount of flow through a BPF [187–190]. Air flows through BPFs have been reported up to 22 L/min [187]. It has been recognized that the air escaping from a BPF does not flow passively from the airways into the pleural space but instead participates to some degree in physiologic gas exchange.…”
Section: Pleural Effusions In the Icumentioning
confidence: 99%
See 2 more Smart Citations
“…Although not a common cause for bpf, barotrauma-induced fistulas have the same consequences of any bpf: maldistribution of the ventilation and perfusion relationship that can result in hypoxemia, hypercapnia, and increased mortality [47]. Also, the volume of continuing gas loss from such fistulas [48,49] may be dependent on peak airway pressure during inspiration, PEEP, and the amount of suction applied to the chest tube drainage system [48][49][50]. Gas that escapes through the fistula tract has often participated in gas exchange but usually not enough to compensate for the overall ventilation and perfusion mismatch [49,51,52].…”
Section: Mechanisms Of Injurymentioning
confidence: 99%