1981
DOI: 10.1111/j.1365-2818.1981.tb01200.x
|View full text |Cite
|
Sign up to set email alerts
|

Measuring error and sampling variation in stereology: comparison of the efficiency of various methods for planar image analysis

Abstract: SUMMARYAn evaluation is made of the relative efficiency (precision of the final estimate per unit time of measurement on a given set of sections) of different methods for planar analysis aimed at estimating aggregate, overall stereological parameters (such as Vv, Sv). The methods tested are point‐counting with different densities of test points (4 ≤ PT ≤ 900 per picture), semiautomatic computer image analysis with MOP and automatic image analysis with Quantimet, for obtaining Vv and Sv estimates. One biologica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
108
1
4

Year Published

1982
1982
2008
2008

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 198 publications
(117 citation statements)
references
References 1 publication
4
108
1
4
Order By: Relevance
“…Para a análise da densidade de área do tecido conjuntivo intramuscular foi utilizado o sistema de planimetria por contagem de pontos (14) , sendo a quantificação realizada por um retículo com quadrados de 2.500µm 2 contendo 56 intersecções de reta. Foram contados os pontos coincidentes no endomísio e perímisio, em cinco áreas por corte, sendo cinco cortes por animal, perfazendo um total de 1.400 pontos por animal.…”
Section: Métodosunclassified
“…Para a análise da densidade de área do tecido conjuntivo intramuscular foi utilizado o sistema de planimetria por contagem de pontos (14) , sendo a quantificação realizada por um retículo com quadrados de 2.500µm 2 contendo 56 intersecções de reta. Foram contados os pontos coincidentes no endomísio e perímisio, em cinco áreas por corte, sendo cinco cortes por animal, perfazendo um total de 1.400 pontos por animal.…”
Section: Métodosunclassified
“…39 To obtain compartment volumes rapidly, we adapted the stereological method of point counting, after we found planimetry to be inaccurate and time consuming. 40 ' 41 We obtained point counts of the following structures: cortex, white matter, thalamus, striatum, hippocampus, ventricle, and visible lesions. We divided the total number of points falling on each compartment by the total number of points falling on the entire cerebrum to determine the proportion of the cerebrum made up by each compartment.…”
Section: Methodsmentioning
confidence: 99%
“…Para a análise da densidade do tecido conjuntivo intramuscular foi utilizado o sistema de planimetria por contagem de pontos 19 , e a quantificação foi realizada por meio de um retículo com quadrados de 2500 μm 2 contendo 56 intersecções de reta. Foram contados os pontos coincidentes no endomísio e perimísio, em 5 áreas por corte, sendo 5 cortes por animal, perfazendo um total de 1400 pontos por animal.…”
Section: Methodsunclassified