2019
DOI: 10.1109/jsen.2018.2882367
|View full text |Cite
|
Sign up to set email alerts
|

Measuring Dielectric Properties for Sensing Foreign Material in Peanuts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 15 publications
0
8
0
Order By: Relevance
“…The microwave attenuation of corn is greater than that of rice under similar moisture content. The attenuation A for different samples can be calculated by substituting |E C | maxs into equation (9). When the sample container is empty, |E C | maxe is 2869.2 mv.…”
Section: Attenuation Of the Traveling-standing Microwavementioning
confidence: 99%
See 2 more Smart Citations
“…The microwave attenuation of corn is greater than that of rice under similar moisture content. The attenuation A for different samples can be calculated by substituting |E C | maxs into equation (9). When the sample container is empty, |E C | maxe is 2869.2 mv.…”
Section: Attenuation Of the Traveling-standing Microwavementioning
confidence: 99%
“…By substituting equations (9) and (11) into equation (12), the following expression is obtained for c:…”
Section: Ricementioning
confidence: 99%
See 1 more Smart Citation
“…The model has been proven effective for the moisture determination of wheat, corn, soybeans, and peanuts (with a standard error of less than 0.97%) [1]. In particular, a shelled peanut moisture determination device was developed by using free-space method (the standard error less than 0.55%), and successfully applied it in the peanut drying field [18,19,20,21]. The free space method can be used to calculate the complex permittivity of grain by measuring the attenuation and phase change of the microwave propagated through the grain.…”
Section: Introductionmentioning
confidence: 99%
“…To prevent the diffraction at the edges of the sample holder and the multiple reflections in the sample holder, the size of the cross-section and the thickness of the sampler holder must be large enough. The sizes of the sample holder in their studies [20,21] were 22.2 cm × 13.3 cm × 21.9 cm (4.5 L) and 4.4 cm × 4.4 cm × 12 cm (243 mL), respectively. This makes the measuring device bulky and difficult to carry, limiting its scope of application.…”
Section: Introductionmentioning
confidence: 99%