2014
DOI: 10.1016/j.nimb.2014.04.017
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of inner-shell characteristic X-ray yields of thick W, Mo and Zr targets by low-energy electron impact and comparison with Monte Carlo simulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 38 publications
0
3
0
Order By: Relevance
“…Bote et al (2008) showed that K and L X-ray yields calculated by using PENELOPE were in reasonably good agreement with experimental measurements taken from the literature. Li et al (2014) and Zhao et al (2015) carried out their own X-ray yield measurements and showed that their experimental data compared favorably, to within ~10%, with the predictions of PENELOPE. More recently, Moy et al (2015) performed new absolute X-ray yield measurements for several high- Z element materials, which were found to agree satisfactorily with the predictions of PENEPMA.…”
Section: Examples Of Applications Of Penepmamentioning
confidence: 97%
“…Bote et al (2008) showed that K and L X-ray yields calculated by using PENELOPE were in reasonably good agreement with experimental measurements taken from the literature. Li et al (2014) and Zhao et al (2015) carried out their own X-ray yield measurements and showed that their experimental data compared favorably, to within ~10%, with the predictions of PENELOPE. More recently, Moy et al (2015) performed new absolute X-ray yield measurements for several high- Z element materials, which were found to agree satisfactorily with the predictions of PENEPMA.…”
Section: Examples Of Applications Of Penepmamentioning
confidence: 97%
“…In this paper, the experimental setup is similar to that of Li et al [41] and Zhao et al [42]. In order to obtain more accurate experimental data, the deep Faraday cup was redesigned and its schematic drawing is shown in figure 1.…”
Section: Methodsmentioning
confidence: 99%
“…The reliability of PENEPMA and PENELOPE has been assessed by our group as well as by other researchers through systematic comparisons of simulated and experimental X-ray spectra from bulk samples [21][22][23], X-ray yields from bulk samples [24][25][26][27], k-ratios from thin films on substrates [28], and k-ratios from material couples [29,30]. Examples of recent applications of PENEPMA or PENELOPE in EPMA include the study of secondary fluorescence effects in bulk samples and near phase boundaries [31,32], the analysis of inclusions in steel [33], the simulation of energy-dispersive spectra for automated materials identification [34,35], the determination of the detector efficiency for standard-less analysis [36] or the examination of carbon contamination effects in high-resolution EPMA [37].…”
Section: Examples Of the Application Of Penepmamentioning
confidence: 99%